ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH SUB- COOLING AND SUPER HEATING WITH THREE DIFFERENT REFRIGERANTS FOR AIR-CONDITIONING APPLICATIONS
Journal Title: International Journal of Engineering Sciences & Research Technology - Year 30, Vol 5, Issue 11
Abstract
This paper presents the simulated results of vapour compression system with sub-cooling and superheating and to compare the system performance for three refrigerants i.e. R22, R410A and R32. For simulation 1 “TR” (Ton of Refrigeration) capacity of air conditioning unit was considered and compared the performance with liquid sub cooling and vapour superheating at different temperature and pressures. For analysis R22 experimental results were considered and simulated for R410A and R32 refrigerants. The simulated results for sub-cooled in the refrigeration system positively affected the system performance and all the investigated refrigerants benefited from the performance improvement. An increase in the sub- cooling and superheating reduced the compressor work input and increased the coefficient of performance. The COP for R22, R410A and R32 are 2.33, 3.36 and 3.63, i.e. with compare to R410A and R22 the refrigerant R32 yields 7.34% and 36% higher COP. The refrigerant charge in to the vapour compression cycle was, for R22, R410A and R32 are 0.8 kg, 0.8 kg and 0.56 kg which determine the size of compressor. For the same operating temperature and pressures the cooling capacity for R32 is higher than the R22 refrigerant. And also reduces the pressure ratio and increases both refrigeration mass flow rate and coefficient of performance.
Authors and Affiliations
Dr. Boda Hadya*
REVIEW ON METHODS TO REDUCE DELAMINATION IN COMPOSITE LAMINATE
Composite material has much more advantage and application than metal. This is mainly because of their excellent mechanical properties with low density and ease of manufacturing, but failure mechanism of composite...
Experimental Study on Cold Formed Steel Composite Metal Deck Slab
Composite deck slab is the advanced method of casting concrete slab with profile metal decking used in tensile zone. The decking acts composite with the concrete under service loading. The behavior of a composite...
Optimal Placement of Relay Nodes in Multi-pair Co-Operative Network to Increase System Capacity in WSN
With the advancement of technology the usage of wireless sensor network are increasing day by day. There are two types of sensor networks: Single tiered and multi-tiered [5]. In single tired sensor network there i...
MODEL FOR PERFORMANCE EVALUATION OF A FLEXIBLE PRODUCTION SYSTEM
The evolution of production systems was motivated by two important factors, increasing productivity on one hand and increasing the number of types of products that can be made in the system, on the other hand. Whe...
OPTIMIZING THE PERFORMANCE OF THERMAL POWER PLANTS
Failure of boiler tubes has been a familiar phenomenon in power plants resulting in unscheduled plant shut down; in consequence, there are heavy losses in industrial production. The failure of boiler tubes appears...