COMPARISON AMONG CROSS, ONBOARD AND VICARIOUS CALIBRATIONS FOR TERRA/ASTER/VNIR

Abstract

 Comparative study on radiometric calibration methods among onboard, cross and vicarious calibration for visible to near infrared radiometers onboard satellites is conducted. The data sources of the aforementioned three calibration methods are different and independent. Therefore, it may say that the reliable Radiometric Calibration Accuracy: RCC would be the RCC which are resemble each other two of three RCCs. As experimental results, it is found that vicarious and cross calibration are reliable than onboard calibration. Also vicarious calibration based cross calibration method is proposed here. The proposed cross calibration method should be superior to the conventional cross calibration method based on band-to-band data comparison. Through experiments, it is also found that the proposed cross calibration is better than the conventional cross calibration. The radiometric calibration accuracy of the conventional cross calibration method can be evaluated by using the proposed cross calibration method.

Authors and Affiliations

Kohei Arai

Keywords

Related Articles

 Developing a Mathematical Model to Detect Diabetes Using Multigene Genetic Programming

 Diabetes Mellitus is one of the deadly diseases growing at a rapid rate in the developing countries. Diabetes Mellitus is being one of the major contributors to the mortality rate. It is the sixth reason for death...

 Method for Reducing the Number of Wild Animal Monitors by Means of Kriging

 Method for reducing the number of wild animal monitors is proposed by means of Kriging. Through wild animal route of simulations with 128 by 128 cells, the required number of wild animal monitors is clarified. Then...

 Accurate Topological Measures for Rough Sets

 Data granulation is considered a good tool of decision making in various types of real life applications. The basic ideas of data granulation have appeared in many fields, such as interval analysis, quantization, r...

 A Semantic-Aware Data Management System for Seismic Engineering Research Projects and Experiments

 The invention of the Semantic Web and related technologies is fostering a computing paradigm that entails a shift from databases to Knowledge Bases (KBs). There the core is the ontology that plays a main role in en...

 The Influence of Stubborn Agents in a Multi-Agent Network for Inter-Team Cooperation/Negotiation

 When teams interact for cooperation or negotiation, there are unique dynamics that occur depending on the conditions. In this paper, a multi-agent system is used under the restrain of a network structure to model t...

Download PDF file
  • EP ID EP157084
  • DOI -
  • Views 134
  • Downloads 0

How To Cite

Kohei Arai (2013).  COMPARISON AMONG CROSS, ONBOARD AND VICARIOUS CALIBRATIONS FOR TERRA/ASTER/VNIR. International Journal of Advanced Research in Artificial Intelligence(IJARAI), 2(10), 14-18. https://europub.co.uk/articles/-A-157084