Abstract

 This paper presents a method for obtaining the desired reference current for Voltage Source Converter (VSC) of the Shunt Active Power Filter (SAPF) using Synchronous Reference Frame Theory. The method relies on the performance of the Proportional-Integral (PI) controller for obtaining the best control performance of the SAPF using Particle Swarm Optimization (PSO). SAPF compensates the harmonics by injecting a compensating current which is equal in magnitude but opposite in phase to the disturbance in the system. The current controller based on Triangular Carrier Current Controller is used to generate the gate pulses. Compensation current is generated to track command current so as to eliminate the harmonic current of non-linear load and reduced total harmonic distortion (THD), improved accuracy and strong robustness in the presence of parameters variation and nonlinear load. The results of simulation study of APF control technique presented in this paper are found quite satisfactory to eliminate harmonics and reactive power components from source current

Authors and Affiliations

Ekhlas Mhawi Thajeel*

Keywords

Related Articles

 Finite Element Method Based Analysis into Rotary Forging of AXI-Symmetric Aluminium Disc

 The present economic situation in the world has been driving the forging industry even at more competitive environment. Finite element simulation became an important tool in the forging industries because of avail...

 Phytochemial Screening of Acanthus montanus (Nees) T. Anderson and Crinium jagus (Thomps) Dandy Extracts and their Potential for Controlling rot fungi of Stored Cocoyam (Colocasia esculenta) (L.) (Schott)

 Phytochemical screening of the crude extracts of Acanthus montanus (Nees) T. Anderson and Crinium jagus (Thomps) Dandy was carried out to determine the bioactive components of the two plants. Results revealed the...

 EXPERIMENTAL STUDY ON BEHAVIOUR OF CONCRETE USING SELF CURING AGENTS

 Concrete is most widely used construction material due to its good compressive strength and durability. Depending upon the nature of work, the constituent materials; cement, fine aggregate, coarse aggregate and wa...

CONJUGATE MIXED CONVECTION THROUGH PERFORATED EXTENDED SURFACES

Some important results of experimental studies on perf orated fins with different configurations having equal weight are presented. This study wa s performed by considering effect of both c onductio...

 Content Protection through Reversible Watermarking Technique

 This paper proposes a steganalysis scheme for detecting reversible contrast mapping (RCM) watermarking. Lossless data hiding is a technique that used to embed secret message into media for generating the stego ima...

Download PDF file
  • EP ID EP100754
  • DOI -
  • Views 57
  • Downloads 0

How To Cite

Ekhlas Mhawi Thajeel* (0).  CONTROL SCHEMES FOR SHUNT ACTIVE FILTERS TO MITIGATE HARMONICS USING TRIANGULAR CARRIER CURRENT CONTROLLER. International Journal of Engineering Sciences & Research Technology, 4(8), 758-762. https://europub.co.uk/articles/-A-100754