Abstract

 This paper presents a method for obtaining the desired reference current for Voltage Source Converter (VSC) of the Shunt Active Power Filter (SAPF) using Synchronous Reference Frame Theory. The method relies on the performance of the Proportional-Integral (PI) controller for obtaining the best control performance of the SAPF using Particle Swarm Optimization (PSO). SAPF compensates the harmonics by injecting a compensating current which is equal in magnitude but opposite in phase to the disturbance in the system. The current controller based on Triangular Carrier Current Controller is used to generate the gate pulses. Compensation current is generated to track command current so as to eliminate the harmonic current of non-linear load and reduced total harmonic distortion (THD), improved accuracy and strong robustness in the presence of parameters variation and nonlinear load. The results of simulation study of APF control technique presented in this paper are found quite satisfactory to eliminate harmonics and reactive power components from source current

Authors and Affiliations

Ekhlas Mhawi Thajeel*

Keywords

Related Articles

 HIDING OF DATA USING STEGANOGRAPHY TECHNIQUE

 So as to have a mystery offering of information, visual cryptography plan permits imparting a mystery picture to information installed in it. Existing routines in picture steganography concentrate on implanting my...

ASSESSMENT OF WATER BALANCE OF A WATERSHED USING SWAT MODEL FOR WATER RESOURCES MANAGEMENT

An attempt has been made in this study to assess the hydrological behavior of the Kurumali sub basin of Karuvannur river basin using SWAT model and other geospatial technologies. All the thematic maps and attribute info...

SIMULATION OF PARABOLIC LEAF SPRING FOR HEAVY COMMERCIAL VEHICLE USING FEA

Leaf springs are special kind of spring used in automobile suspension system mostly. The automobile industry has shown increased interest in the replacement of steel spring with fiber glass composite leaf spring beca...

 EXPERIMENTAL AND NUMERICAL INVESTIGATION TO AVOID EXTERNAL CONDENSATION ON FLIPPER MULLION IN FRENCH DOOR REFRIGERATOR

 In French-style doors a flipper mullion is provided to have an air tight seal to avoid heat leakage between the doors. It is attached to one of the French doors through both of the hinge members. However, due...

EFFECT OF DURATION AND TEMPERATURE OF CURING ON COMPRESSIVE STRENGTH OF FLY ASH BASED GEOPOLYMER CONCRETE

The optimum temperature and duration of curing is essential in geopolymerization reaction to achieve higher strength. As such, fly ash based geopolymer concrete were prepared by varying the curing temperature of 600, 90...

Download PDF file
  • EP ID EP100754
  • DOI -
  • Views 73
  • Downloads 0

How To Cite

Ekhlas Mhawi Thajeel* (0).  CONTROL SCHEMES FOR SHUNT ACTIVE FILTERS TO MITIGATE HARMONICS USING TRIANGULAR CARRIER CURRENT CONTROLLER. International Journal of Engineering Sciences & Research Technology, 4(8), 758-762. https://europub.co.uk/articles/-A-100754