Cooling analysis of self Activating Bi-Metallic Valve using Thermo –Structural Coupled FEA

Journal Title: International Journal of Modern Engineering Research (IJMER) - Year 2013, Vol 3, Issue 6

Abstract

 To replace electronically actuated valves or to provide second layer of safety in case of electronic alfunction a totally mechanically actuated valve & warning system is designed. The process for which valve optimization is carried out is the process of nitrousoxide generation from ammonium nitrate. The main challenge in the process was maintaining temperatures below 200◦C as above this temp ammonium nitrate becomes explosive & safety risks are involved. The secondary objective was to maintain this temperature above 170◦C as below this temperature reaction does not proceed. All these objectives are fulfilled by employing a bimetallic valve .The primary purpose of the self actuation is achieved by selecting proper dimensions of the valve & designing warning system in which desirable deflection of the bimetallic strip is achieved. But main problem arises during cooling as there is the possibility of the bimetallic strip of may lead to highcrushing stresses. The main requirement while carrying out cooling is that the bimetallic strip should again rest on the flow casing as previous i.e. it should close valve again while cooling & not crush on the flow casing or deflects beyond flow casing.

Authors and Affiliations

Swati Paithankar

Keywords

Related Articles

 Heuristic Approach for Secure Energy Efficient Routing in Mobile ad hoc Network

 In today’s scenario, energy savings and security is the major problem in all kind of the networks. MANET is a network, which is very popular due to its unique characteristics from all the other types of networks. M...

Performance of MMSE Denoise Signal Using LS-MMSE Technique

This paper presents performance of mmse denoises signal using consistent cycle spinning (ccs) and least square (LS) techniques. In the past decade, TV denoise technique is used to reduced the noisy signal. The main drawb...

 An Optimal Risk- Aware Mechanism for Countering Routing Attacks in MANETs

 Mobile Ad Hoc Networks (MANET) are a distributed and self configuring wireless networks. MANETs does not have a predefined network infrastructure. Application of MANET is benefited in areas such as disaster relief,...

 A Novel Method for Preventing Selective Jamming Attacks in Wireless Networks

 Wireless networks are susceptible to numerous security vulnerabilities due to the open nature of the wireless medium. Anyone with a transceiver can eavesdrop on ongoing transmissions, block the transmission of legi...

An Integrated Inventory Optimization for Deteriorating Products under Multi - Echelon Just In Time (JIT)

This paper deals with the deterioration inventory model which focuses on optimally coordinating Just In Time (JIT) policy among all the partners with various issues in the supply chain in order to minimize the joint...

Download PDF file
  • EP ID EP136384
  • DOI -
  • Views 83
  • Downloads 0

How To Cite

Swati Paithankar (2013).  Cooling analysis of self Activating Bi-Metallic Valve using Thermo –Structural Coupled FEA. International Journal of Modern Engineering Research (IJMER), 3(6), 3505-3510. https://europub.co.uk/articles/-A-136384