Experimental Studies on Mortar Using Glass Fibers

Abstract

 An experimental program was carried out to evaluate the properties of cement Mortar. Compressive strength test, splitting tensile strength test and Water absorption test were performed and the results were analysed statistically. Glass fibres can greatly increase the properties of cement Mortar. Specimens containing fibre of 0.00%, 0.10%, 0.20% and 0.30% are prepared and tested in this work. It is demonstrated that a certain amount of fibres enhances the compressive, splitting tensile strength and Water absorption capacity of the fibre reinforced cement mortar. The Compressive strength of mortar was increased to 111.78 % at 7 days & 28.46 % at 28days and splitting tensile strength was increased by 115.15 % at 7 days & 40.00 % at 28 days.

Authors and Affiliations

Divyeshkumar D. Paradava*1,

Keywords

Related Articles

 DEVELOPMENT OF ROBOTIC SWARMS FOR A SPORTS GAME

 There are myriad occasions where human inclusions in a situation can be replaced by a robot which does the same task with ease and in a shorter duration of time. With the advent of robotics in each and every field...

 An Approach for Unreliability of Direct Methods-Optimal Solution of Transportation Problem

 The Transportation problem is a special class of Linear Programming Problem. It deals with shipping commodities from different sources to various destinations. The objective is to determine the shipping schedule t...

 Synthesis and Characterization of Biomaterial Hydroxyapatite

 Hydroxyapatite (HA) is successfully used as a bio implant material because it resembles the bone apatite up to a great extent and possesses good biocompatibility. In the present study, HA powder has been synthesiz...

 EXPERIMENTAL AND COMPUTATIONAL STUDY OF SOME IMIDAZOLE DERIVATIVES AS CORROSION INHIBITORS FOR COPPER IN SULFURIC ACID MEDIUM

 Corrosion behavior of copper in 1.0 M Sulfuric acid containing either Imidazole (IM), 2-Methylimidazole (MIM) or Benzimidazole (BIM) was investigated experimentally via weight loss measurements and UV-Spectroscopy...

 Investigation of Parallel Generator Unit-Connection effects on Third Harmonic Stator Earth Fault Protection

 Third harmonic protection is one of the methods used for preventing damage to generator stator winding due to earth fault. Its effects have been investigated for single generator unit connection. However, there is...

Download PDF file
  • EP ID EP122425
  • DOI -
  • Views 87
  • Downloads 0

How To Cite

Divyeshkumar D. Paradava*1, (30).  Experimental Studies on Mortar Using Glass Fibers. International Journal of Engineering Sciences & Research Technology, 3(5), 528-532. https://europub.co.uk/articles/-A-122425