Flow-Injection Spectrophotometric Determination Of Nitarate In Wastewater Samples Using Diazotization Coupling Reaction

Journal Title: Applied Science Reports - Year 2013, Vol 3, Issue 2

Abstract

 The development and application of a simple and sensitive batch and flow- injection spectrophotometric method for nitrite and nitrate determinations had been described. In this study, the method was based on the diazo-coupling reaction between acidified NDMPDAH and resorcinol. Under alkaline conditions the azo dye was formed, which absorption reaches maximum at 472 nm. Nitrate was reduced to nitrite in amalgamated cadmium reductor column and analyzed as nitrite. The developed flow-injection analysis system was applied for determination of nitrite and nitrate in the linear range of (0.2 – 5.0) μg/ml and (0.3 – 6.0) μg/ml, with detection limits of 0.09 μg/ml and 0.15 μg/ml and rates of sampling 70 and 60 S/h, with the RSD% and Error% of (0.243%, 0.548%) and (– 1.6%, + 1.66%), respectively, by using sample volume of 125 μl. The influences of some interference on the batch and flow-injection spectrophotometric determination of nitrate have been described. To eliminate the effect of some cationic interferences such as (Cr3+, Cd2+, Co2+, Fe3+, Ni2+, Mn2+ and Cu2+) two methods have been used; the first was column of cationic exchanger (H+–form) with 25-cm length of packing and flow rate of 0.5 ml/min, while the second was using 5.0% of EDTA solution, the results showed that EDTA solution gave superior results than the use of the cation exchanger column. 3.25 ml of 5.0% EDTA solution was charged with the sample of nitrate before injection to avoid the influence of those cations.Nitrate content of wastewater samples in different locations in Erbil city have been successfully determined using the flow-injection analysis method.

Authors and Affiliations

Nabil A Fakhre, Hemn A Qader

Keywords

Related Articles

Delay in Container Handling Operation and Container Port Competitiveness

The aim of this research is Delay in Container Handling Operation and Container Port Competitiveness using Hybrid ANP and TOPSIS grey method. To reach research goal, the daily data of Khorramshahr container terminal even...

 Flow-Injection Spectrophotometric Determination Of Nitarate In Wastewater Samples Using Diazotization Coupling Reaction

 The development and application of a simple and sensitive batch and flow- injection spectrophotometric method for nitrite and nitrate determinations had been described. In this study, the method was based on the di...

 Effects of waxing materials and storage periods on physico-chemical properties of trifoliate yam (Dioscorea dumetorum)

 The effect of different waxing materials (bee wax, palm wax and paraffin wax) and storage period (0, 2, 4, 6, 8 weeks) on some physico-chemical parameters of Dioscorea dumetorum tubers was assessed. Harvested tuber...

 The use of ICT and technology in language teaching and learning

 The use of technology in language teaching and learning is an interesting issue for all teachers and practitioners in the field. The importance of this issue is reflected in the large amount of the literature conce...

Ethnobotanic Contribution of Cameroon: Anti- Diabetic Plants Inventory in the Nkoung–Khi Division West Region Cameroon

 The inventory of medicinal plants used in traditional medicine in the Nkoung –Khi (Cameroon),a field investigation was brought nearer to the people concerned notably the healers ,herbalist, midwives and people suf...

Download PDF file
  • EP ID EP126257
  • DOI -
  • Views 146
  • Downloads 0

How To Cite

Nabil A Fakhre, Hemn A Qader (2013).  Flow-Injection Spectrophotometric Determination Of Nitarate In Wastewater Samples Using Diazotization Coupling Reaction. Applied Science Reports, 3(2), 125-131. https://europub.co.uk/articles/-A-126257