HARMONIC ANALYSIS OF ROTARY COMPRESSOR USING FEA

Abstract

 Frequency response analysis is performed out under the application of the self weight of the rotary compressor as the force on the model with in the Frequency range of 0-100 Hz. This particular range is selected since the working range of frequency of the compressor is from 50-60 Hz. In Harmonic analysis, displacement is measured in the frequency range of 0Hz to 100Hz dividing the frequency range into 10 sub steps. The response of the system to this excitation frequency is measured at the three locations that are at each Leg. A node near to each leg is selected and at that node, its displacements are measured along all the directions. Analyzing all the three mounting plates using Harmonic Analysis, the displacement response in the plates with the range of excitation frequency is determined. Considering them sequentially 211mm plate, 176mm plate and 176mm flat plate responses are determined and compared their stability.

Authors and Affiliations

D. Venugopal , P. Ravinder Reddy

Keywords

Related Articles

 4-CLASS MOTOR IMAGERY CLASSIFICATION FOR POST STROKE REHABILITATION USING BRAIN-COMPUTER INTERFACE

 Brain-Computer Interface (BCI) is a mechanism that helps in the control/communication of one’s environment through the brain signals obtained directly from the brain via an EEG signal acquisition unit. A BCI i...

 SPATIAL AND SEASONAL VARIATION IN GROUND WATER QUALITY OF RIVER PALAR BASIN USING MULTIVARIATE TECHNIQUES

 In this study, spatial and seasonal variation in ground water quality of palar river basin using multivariate statistical techniques, such as cluster analysis, principle component analysis and factor analysis. wat...

 Intuitionistic (α, β)- Fuzzy Hv-Subgroups

 Atanassov introduced the notion of intuitionistic fuzzy sets as a generalization of the notion of fuzzy sets. In this paper we introduce the concept of an intuitionistic (α β, ) -fuzzy Hv-subgroups of an Hv-groups...

 LDPC DECODING OF NAND FLASH MEMORY BY SOFT DECISION ERROR CORRECTION METHOD

 The reliability of data stored in an high-density Flash memory devices tends to drop off rapidly because of the reduced cell size and multilevel cell technology. The Soft-decision error correction algorithms make...

DESIGN AND ANALYSIS OF FLUID VISCOUS DAMPER FOR VIBRATION REDUCTION IN HAND HELD POWER MACHINERY

Hand - arm vibration (HAV) is vibration transmitted from a work processes into workers’ hands and arms. It can be caused by operating hand - held power tools, hand - guided equipment, or by holding materials bei...

Download PDF file
  • EP ID EP163360
  • DOI -
  • Views 80
  • Downloads 0

How To Cite

D. Venugopal, P. Ravinder Reddy (2015).  HARMONIC ANALYSIS OF ROTARY COMPRESSOR USING FEA. International Journal of Engineering Sciences & Research Technology, 4(1), 621-627. https://europub.co.uk/articles/-A-163360