 The ability of the circuit breakers to interrupt the electrical current in circuits with capacitive load it is tested and verified in testing laboratories. During the test, the capacitive type of load impedance simulates an overhead line or an underground cable that works with no load impedance. The transient behaviour which appears at the opening of electric circuits having capacitive load impedance can determine the appearance of some dangerous over-voltages for line, cables and equipments. After testing, at the circuit interruption, it is possible to be residual electrical charge on capacitors. This endangers the lives of people who configures the test scheme. The paper describes a device that monitors the voltage on the capacitors that are connected to busbars and which alerts the staff about the presence of electric charges remaining at the end of the test. A referral unit is mounted near the bars to that are connected capacitors, while warning unit is mounted in the place where can be observed by personnel that configure the test schemes. Two variants of the device are presented. The results, obtained with the device during carrying out tests, both in the laboratory and in operation, are presented into the final section of the paper.

Authors and Affiliations

Marinel Popescu

Keywords

Related Articles

PROGRESS IN THE PRODUCTION OF HIGH VOLTAGE AND EXTRA HIGH VOLTAGE CABLES

The transmission and distribution of electrical energy requires efficient and reliable networks with low losses. Traditionally this role has been fulfilled by overhead networks, which have been considered as a lower cos...

Analysis of Losses in Brushless Direct Current Motors and Their Influence upon Operation Characteristics

Researches regarding the optimum design and construction of brushless direct current motors are very present, owing to their use in small-dimension vehicles (electrical scooter, electrical bicycle, motor-scooters, electr...

Study of the Reactive Power Side Effects for Tariff and Compensation Purpose at the Transmission Networks’Users

The reactive power flows affect voltages, losses and transmission capacities. Thus MVAR flows are a matter of increasing concern for the grid operators and the Romanian Regulatory Authority for Energy has established the...

ON THE AMPACITY OF INSULATED CONDUCTORS IN CONDUIT

In the paper, a practical method for determining the smallest allowable cross-sectional area of circuit insulated conductors or single-core cables in conduit buried in a thermally insulated wall is proposed. A way to obt...

New Aspects on the Frequency Splitting and Bifurcation Phenomena in Wireless Power Transfer Systems

This paper focuses on the frequency splitting and bifurcation phenomena that appear in the wireless power transfer systems. These two phenomena are analyzed for different possible configurations of the magnetically coupl...