INVESTIGATION OF LEAKAGE CURRENT OF INSULATOR USING ARTIFICIAL NEURAL NETWORK

Abstract

 In order to improve the reliability of power transmission lines, one of the key issues is to reduce the hazard of contamination flashovers. At the present time, the most efficient way is to clean (or replace) the heavily polluted insulators. This study laboratory based tests were carried out on the model under ac voltage at different pollution levels. A new model based on artificial neural network has been developed to predict flashover from the analysis of leakage current. The input variable to the artificial neural network are mean (Imean), maximum (Imax), and standard deviation (I) of leakage current extracted along with the input voltage (V) and relative humidity (RH). The target obtained was used to evaluate the performance of the neural network model. The comparison of the simulated and actual (measured) results demonstrates that the ESDD prediction model from the stage characteristics.

Authors and Affiliations

A. Ananth*

Keywords

Related Articles

 KINETIC OF THE PHYSICAL QUALITY CHANGES DURING DEEP FAT FRYING OF SWEET POTATO CHIP

 Investigation was carried out to study kinetics of moisture loss, oil uptake, lightness and textural changes during deep fat frying of sweet potato (Ipomoea batatas L.) chip. Sweet potato slides of 2mm thickness w...

PERFORMANCE ANALYSIS OF AIR COOLED WATER COOLER BY USING ECO - FRIENDLY REFRIGERANT S AS A POSSIBLE SUBS TITUTE OF R134A

The EU F - gas regulation would take effect from January 1,2015. The regulation implies an HFC phase - down from 2015 to 2030 by means of bans on high GWP refrigerants. Especially R134a is under pressure and likely...

 Integral Solution of Sextic Equatio

 We obtain infinitely many many non-zero integer quintuples equation with five unknowns 3 3 3 3 5 x y z w x y T + = + + + x, y, z, w and T are presented.

 Response Evaluation of Stairways in RC Frames Under Earthquake Ground Motions

 Stairways, the primary vertical emergency exit routes in multistory buildings, are critically important for egress and access during earthquakes and fires. Seismically damaged stairways have delayed evacuation, im...

 Study and Analysis of IEEE 802.15.4 Media Access Control (MAC)

 The Low rate wireless Personal Area Networks (LR-WPAN) allows the optional use of a superframe structure. The superframe is bounded by network beacons and is divided into 16 equally sized slots. The superframe ca...

Download PDF file
  • EP ID EP101687
  • DOI 10.5281/zenodo.60115
  • Views 75
  • Downloads 0

How To Cite

A. Ananth* (30).  INVESTIGATION OF LEAKAGE CURRENT OF INSULATOR USING ARTIFICIAL NEURAL NETWORK. International Journal of Engineering Sciences & Research Technology, 5(8), 667-672. https://europub.co.uk/articles/-A-101687