INVESTIGATION ON SHUNT ACTIVE POWER FILTER USING PI CONTROLLER

Abstract

 This paper describes the application of PI controller to a three phase shunt active power filter for power quality improvements and reactive power compensation required by a nonlinear load. Most active power filter use PI controller in the voltage/current control loop. The use of PI controller is simple and easy to implement. However, the design of PI controller requires a precise linear mathematical model. Switching signals for voltage sourced PWM converter are generated through hysteresis current control. The performance of shunt active power filter is evaluated using MATLAB/SIMULINK simulation.

Authors and Affiliations

Gayatri J. Ghewade

Keywords

Related Articles

SYNTHESIS AND CHARACTERIZATION OF TiO2NANOCRYSTALS BY SOL-GEL METHOD AND STUDY THE EFFECT OF CALCINATION TEMPERATURE ON ITS PHOTOCATALYTIC ACTIVITY

TiO2 nanoparticles were prepared by a simple sol-gel method at different calcinations temperature. The prepared samples were characterized by X-ray diffraction andUV visible spectroscopy techniques. Hydroxyl radicals (•...

 AN ENHANCED STRATEGY IN BEACON OVERHEAD AND PDR IN MANET USING GEOGRAPHIC ROUTING STRATEGIES

 MANET is self-configured Mobile Ad hoc network of mobile nodes connected via random topology. The main issue in MANET is the selection of best path between any two nodes. Routing in MANET is to find the effici...

 Comparision of a New Approach of Balancing the Load in Cloud Environment with the Existing Techniques

 In cloud Computing, Load Balancing is essential for efficient operations in distributed environments. As Cloud Computing is growing rapidly and clients are demanding more services and better results, load balancin...

 HYBRID APPROACHES FEATURE SUBSET SELECTION: A REVIEW

To overcome the weakness of filter and wrapper approaches, many researchers combined both the methods together. The hybrid approaches are intended to be computationally more effective than wrapper approach as well as yi...

 QOS AWARE BANDWIDTH CONSTRAINED PRECEDENCE BASED ROUTING PROTOCOL FOR MOBILE AD-HOC NETWORKS

 A Mobile Ad-hoc network (MANETs) is a dynamically formed self-configured network by an autonomous system of mobile nodes connected by wireless links. With the advancements of wireless technology, the necessity...

Download PDF file
  • EP ID EP159088
  • DOI -
  • Views 78
  • Downloads 0

How To Cite

Gayatri J. Ghewade (2015).  INVESTIGATION ON SHUNT ACTIVE POWER FILTER USING PI CONTROLLER. International Journal of Engineering Sciences & Research Technology, 4(12), 1-6. https://europub.co.uk/articles/-A-159088