MEASUREMENT OF INTERNAL CONVERSION COEFFICIENT Of 280kev γ – RAYS IN 203Hg

Abstract

 The measurement of the internal conversion coefficient of 280keV γ – ray in 203HG have been investigated by means of calibrated 2ʺ x 2ʺ NaI(Tl)(scintillation detector which is sodium iodide activated with small amount of thallium) γ – rays spectrometer, using the standard γ – rays sources Co67 and Ba133 as shown in Table(1), and prepared a source of Hg203 from Hg203Cl2. It have been used some heavy element Au198 isotope Ti81[3, 6, 9, 12,13, 15]. The total internal conversion coefficient of a γ – ray may be calculated by taking the ratio of the number of detected X – ray to the γ – ray, Equation (14). In this workit have been discussed some important γ – ray interaction processes like photoelectric effect, Compton scattering and pair production etc. through which gamma ray interact with matter and get absorbed in it[1,2,16]. The measured value of internal conversion coefficient of 280KeV γ – ray in Hg203 at various source detector distances in centimeters (0.0, 3.2, and 4.2) which gives internal conversion coefficient (α) 0.230, 0.179 and 0.187 respectively. The average internal conversion coefficient α, of 280 keV γ – ray in Hg203is 0.2. By comparingthe measurement results with the standard value, it had been found that the measured values of internal coefficient of 280 KeVγ – ray in 203Hg was independent of source detector distance which was obvious and came out to be 0.20. Our experiment finding was in good agreement with the earlier reported value as 0.20.

Authors and Affiliations

Zafaran Abdul Fattah

Keywords

Related Articles

INHIBITIVE EFFECT OF WRIGHTIA TINCTORIA LEAVES AS GREEN INHIBITOR FOR MILD STEEL IN ACID MEDIUM

The inhibition efficacy of Wrightia tinctoria leaves (WTL) extract on mild steel in 1.0N hydrochloric acid with various exposure time (24 to 360hrs) and temperature (313 to 333K) are investigated by mass loss measuremen...

 Human Ear Biometric Authentication System

 The ear, as a biometric, has been given less attention, while comparing with other biometrics such as fingerprint, face, Iris. Since it is a relatively new biometric, no commercial applications involving ear recog...

 THE NEW THEORY OF THE ONENESS OF SQUARE AND CIRCLE

 Originally, Pi constant was understood as the ratio of circumference of a circle to its diameter. As the length of the circumference could not be measured due to its curvature, Exhaustion method was adopted for ma...

 A REVIEW ON WIRELESS POWER TRANSFER (WPT) FOR ELECTRIC VEHICLE (EV) APPLICATIONS

 This paper provides the wireless power transfer (WPT) or contactless power transfer (CPT) for charging electric vehicles (EV). This technology is recent method in electrification for transportation, useful for the...

IMPORTANCE OF SOLAR POND

The sun is the largest source of renewable energy and this energy is abundantly available in all parts of the earth. It is in fact one of the best alternatives to the non-renewable sources of energy. One way to tap solar...

Download PDF file
  • EP ID EP154261
  • DOI 10.5281/zenodo.56997
  • Views 57
  • Downloads 0

How To Cite

Zafaran Abdul Fattah (30).  MEASUREMENT OF INTERNAL CONVERSION COEFFICIENT Of 280kev γ – RAYS IN 203Hg. International Journal of Engineering Sciences & Research Technology, 5(7), 403-417. https://europub.co.uk/articles/-A-154261