Performance Characteristics of the R404A Indirect Refrigeration System Using CO2 as a Secondary Refrigerant

Abstract

 In this study, to investigate the performance characteristics of the R404A indirect refrigeration system using CO2 as a secondary refrigerant, the R404A refrigeration system was analyzed experimentally. Under given experimental conditions, the lower the difference between the R404A condensing temperature and the CO2 cooling temperature was, the greater the coefficient of performance (COP) of the total indirect refrigeration system was, including the R404A refrigeration and CO2 refrigerant circulation systems. These findings indicate that the COP of the R404A indirect refrigeration system using CO2 as a secondary refrigerant and the COP of the total refrigeration system are influenced by such variables as the R404A condensation temperature, the efficiency of the R404A internal heat exchanger, and the difference in CO2 cooling temperature, CO2 evaporation temperature, and CO2 mass flow. Therefore, the optimum R404A indirect refrigeration system using CO2 as a secondary refrigerant could be designed by considering these variables

Authors and Affiliations

Jung-In Yoon*

Keywords

Related Articles

 Critical Event Monitoring in WSNS using Level-By-Level Offset Based Wake up Pattern

 This paper proposed to monitor a critical event in wireless sensor networks. Whenever a critical event occurs, the critical event is detected by the nearby sensor nodes. Immediately these sensor nodes should broad...

 A Review on Wireless Oscilloscope Powered by Android

 The normal operation of any signal measuring device, is to take an input and display on a screen so as to measure it & for further processing.Unfortunately, these devices are too bulky and are not readily avai...

 APPROACH TO THE OVERVIEW OF CLOUD COMPUTING, APPLICATION AND FUTURE SCOPE

 Cloud computing has particular characteristics that distinguish it from classical resource and service provisioning environments. The paper aims to provide a means of understanding the model and exploring options...

ADAPTIVE SCHMITT TRIGGER BASED ON OTA DRIVEN BY DIFFERENTIAL INPUT VOLTAGE FOR SETTING QUIESCENT HYSTERESIS AND COMPENSATING AMPLIFIER OFFSET

Schmitt Trigger, first presented by Schmitt in 1938 is extensively used in Pulse Width Modulation Circuits, Sensors, Square Wave Generators, buffers and Sub threshold SRAM. It utilizes the fundamental concept of bi-stab...

 STUDY OF VARIOUS COPY MOVE FORGERY ATTACK DETECTION TECHNIQUES IN DIGITAL IMAGES

 In today’s era of digital technology, security becomes a prominent issue while transferring data from one place to another place. A large amount of data is passed in form of digital images in various areas like mi...

Download PDF file
  • EP ID EP127538
  • DOI -
  • Views 64
  • Downloads 0

How To Cite

Jung-In Yoon* (30).  Performance Characteristics of the R404A Indirect Refrigeration System Using CO2 as a Secondary Refrigerant. International Journal of Engineering Sciences & Research Technology, 3(10), 459-473. https://europub.co.uk/articles/-A-127538