SEISMIC EVALUATION OF REINFORCED CONCRETE BUILDING

Abstract

 In the study of evaluation for retrofitting of any building made up of reinforced concrete is done by using method of inelastic method, capacity curve method etc. Capacity curve which is load deformation plot is output of inelastic method. As this inelastic analysis is non linear static analysis, so load deformation curve is obtained from ANSYS. ANSYS which is based on finite element method is used for performing the non liner static inelastic analysis and cracking pattern can be analyzed in ANSYS. The need of retrofitting of any particular element of any existing building will be obtained by cracking pattern. In this first symmetrical building is analyzed on ANSYS for the procedure development as per ATC-40 then symmetric evaluation is done on unsymmetrical building designed for without considering seismic effect and then same building considering the seismic effect according to IS 1893:2002. These results then compared for suggestion for retrofitting of affected members.

Authors and Affiliations

Deepti Singh *

Keywords

Related Articles

 Comparative Study: Garbage Collector in OODBMS

 This paper addresses the use of garbage collectors for efficient garbage collection in a large object-oriented database. The OODB is partitioned and grouped independently by using information about inter-partition...

CRACKING OF PALM OIL TO PRODUCE OLEOCHEMICALS

The FTIR and GC-MS tests are necessary for identification of oleochemicals produced via cracking. In this research, thermal cracking (without catalyst) and catalytic cracking of palm oil were carried out in a batch reac...

 A SURVEY ON SECURE COMMUNICATION IN PUBLIC NETWORK DURING DISASTER

 Secure communication is possible, when two entities are communicating and do not want/allowed a third party to listen in/enter in. A Disaster is a serious disruption of the functioning of a community or a society...

 IMPLEMENTATION OF MULTIPHASE BIDIRECTIONAL NONISOLATED DC – DC CONVERTER FOR HIGH POWER APPLICATIONS

 The converter has high efficiency due to soft-switching operation in all Multi bridges. Steady-state analysis of the converter is presented to determine the power flow equations, tank currents and soft-switching r...

 RETROFITTING AND STRENGTHENING OF BRIDGES

 This paper presents one bridge which were either rehabilitated or strengthened by using FRP composites. The resulting structure was then tested for the effect after using FRP composites for Rehabilitation and stre...

Download PDF file
  • EP ID EP106250
  • DOI -
  • Views 73
  • Downloads 0

How To Cite

Deepti Singh * (0).  SEISMIC EVALUATION OF REINFORCED CONCRETE BUILDING. International Journal of Engineering Sciences & Research Technology, 4(9), 329-338. https://europub.co.uk/articles/-A-106250