Simulation and Analysis of Second Generation Current Conveyor using 0.18 µm CMOS Technology
Journal Title: International Journal of Engineering Sciences & Research Technology - Year 30, Vol 3, Issue 3
Abstract
A wide bandwidth CMOS realization of high performance dual output second generation (CCII±) current conveyor is presented. second generation current conveyor has the advantages of a wide current and voltage bandwidths, controlled intrinsic resistances at port X, Y and Z. SPICE simulation show that the current and voltage bandwidths are respectively 2.05 GHz and 4.3 GHz for a control current of 26 µA. CCII± is a useful building block for analog circuits, especially for application requiring dual outputs. we use a translinear configuration for second generation current conveyor. The current conveyor is simulated in terms of voltage offset, current offset, current bandwidth and voltage bandwidth in 180nm CMOS technology using Mentor Graphics tools.
Authors and Affiliations
Prachi Parikh
Microwave Irradiation on Synthesis of High Quality Graphene Nano Sheets
Graphene, a single atom thick monolayer sheet of hexagonally arrayed sp2 bonded carbon atoms in honeycomb crystal lattice has a lot of attraction and tremendous attention from the both in experimental and theoret...
OPTIMIZATION OF VALVETRAIN MECHANISM FOR THREE CYLINDER TURBOCHARGED INTERCOOLED GASOLINE ENGINE
Present work descries the effect of in-cylinder pressure in turbocharged gasoline engine, on valvetrain analysis. Consideration of cylinder pressure gives corrected stresses and also it gives scope for reduction in movin...
Model Analysis of Centre Circular Cutout of Laminated Composite Plate and Square Skew Plate by using FEM
A "composite" is when two or more different materials are combined together to create a superior and unique material. This research presents an experimental of the Model analysis of Centre circular laminated compo...
Design of Modified mattresses for patient handling in Hospital
In present day, we see in maximum hospital, transfer of patient from one place to another place that time require maximum labor work. during patient handling, patient and hospital staff suffers from many problems...
REMOVAL OF MALACHITE GREEN DYE FROM AQUEOUS SOLUTION BY ELECTROCOAGULATION WITH STAINLESS STEEL ELECTRODES
In order to see the influence of different variable parameters (inter electrode distance, initial conductivity, time of electrolysis, pH of the solution and initial concentration of dye) and the efficiency to remove Mal...