Simulation of Interline Power Quality Conditioner

Abstract

 This paper proposes to improve the power quality of two feeders in a distribution for a new connection of IUPQC. A UPQC consists of a series dynamic-voltage restorer (DVR) and a shunt active power filter (APF) both joined together by a common DC bus. It is demonstrated how this device can be connected between two independent feeders to regulate the bus voltage of one of the feeders while regulating the current across a load in the other feeder. Since the UPQC is connected between two different feeders (lines), this connection of the UPQC will be called an interline UPQC (IUPQC). The structure, control and capability of the IUPQC are discussed in this paper. The efficacy of the proposed configuration has been verified through simulation studies using Matlab.

Authors and Affiliations

E Yadesh Kumar Yadav*,

Keywords

Related Articles

FEEDBACK MANAGEMENT SYSTEM

The main purpose of this project is to develop a feedback Management System for Engineering college students. This system is developed for only the engineering college students for giving their feedback directly to the...

 [b]PEFORMANCE AND EMISSION CHARACTERISTICS OF WASTE PLASTIC PYROLYSIS OIL IN D.I SINGLE CYLINDER DIESEL ENGINE[/b]

 Environmental concern and availability of petroleum fuels have caused interests in the search for alternative fuels for internal combustion engines.. There is a need to search for alternative fuels for the automob...

 Peristaltic Couple Stress Flow of Blood through Coaxial Channel with Effect of Porous Medium: Blood Flow Study

 Peristaltic couple stress flow of blood through coaxial channel with effect of porous medium: blood flow study. The velocity, pressure gradient, flow rate and pressure rises of blood are investigated by using appr...

 Friction Calibration Using Centre Intrude Specimens

 This research aims to investigate the possibilities of alternative non From literature survey it is observed that resea friction calibration. It is found that ring compression test is recommended as the standard...

 Biomonitoring of trace metal pollution using the Mollusc Bivalve Donax Trunculus and the surface sediment from the Mediterranean coast of Northern Tunisia

 In recent years, as many other Mediterranean coasts, the Gulf of Tunis, situated in the northern eastern coast of Tunisia has been subjected to significant urban, agricultural and industrial extension that might h...

Download PDF file
  • EP ID EP163771
  • DOI -
  • Views 68
  • Downloads 0

How To Cite

E Yadesh Kumar Yadav*, (30).  Simulation of Interline Power Quality Conditioner. International Journal of Engineering Sciences & Research Technology, 3(9), 451-456. https://europub.co.uk/articles/-A-163771