Three Phase Power Factor Correction Using SEPIC In DCM With Isolation

Abstract

 The improvement of power quality are required in AC-DC converters in terms of power factor correction. The PF is improved by reduction of total harmonic distortion at input of ac supply. Also high PF needed precisely regulated dc output. This paper briefly explains a three phase rectifer with high PF using single-ended primary-inductance converter (SEPIC) operating in discontinuous conduction mode with the analysis and design. The high PF at the input ac mains is attained through the use of current control loop. Average current mode control is used in proposed topology. The DCM topology is implemented for attain improved power factor in an effective and simple manner. The advantages of DCM operation are turn-on of the power switches at zero-current, turn-off the output diode at zero-current and simple control circuitry.

Authors and Affiliations

Keywords

Related Articles

Effect of Physical Constraints on the Dynamics of a Multi-Area Interconnected Power System

An attempt is made in this paper to study the dynamic performances of a multi – area interconnected power system considering all possible physical constrains in the power system using conventional integral controllers....

 NEW FRAMEWORK FOR ANALYSIS OF CAPTCHA SECURITY FOR HARD AI PROBLEMS

 The ability area between people and bots in acknowledging connected and distorted figures becomes progressively smaller with advances of segmentation and Optical Character Recognition (OCR) technologies. This trend...

Band Width and Gain Optimization of a Wide Band Gap Coupled Patch Antenna

Band Width and gain optimization of w presented. Using this novel technique the band width can be improved up to 85.21% covering the frequency range from 0.951-2.363 GHz and gain has been improved up to 5.8 dBi. This s...

PLC-BASED SCHOOL AUTOMATION SYSTEM

In our day to day in school we observe that in school too much human effort is required to open and close the gate of school, ring the bell after every 1 hour,and tube lights and fans in the class are on even if there i...

HYBRID INDIRECT SOLAR COOKER WITH LATENT HEAT STORAGE

Solar cooking is the simplest, safest, most convenient way to cook food without consuming fuels or heating up the kitchen. All the conventional solar cooker designs have the disadvantage of inability to cook during off-s...

Download PDF file
  • EP ID EP105617
  • DOI -
  • Views 63
  • Downloads 0

How To Cite

(2014).  Three Phase Power Factor Correction Using SEPIC In DCM With Isolation. International Journal of Engineering Sciences & Research Technology, 3(12), 484-489. https://europub.co.uk/articles/-A-105617