Use of Modern Computing Technique to Improve the Energy Indicators of Drive Motors of the Coal Mills
Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2015, Vol 39, Issue 39
Abstract
In this paper, the authors present a study on the energetic opportunity to replace derated motors of the five mills which are in service at a power plant with other motors by a rated power closer to the actual load. To this end, it has previously been drawn up a suggestive comparative analysis of diagrams of active and reactive power balance in absolute and percentage values for each case of considered constructive variants. Thus for drawing up, using the complete mathematical model (BEMAS) chosen for the asynchronous machine, of the electric balances for different operating regimes of these asynchronous motors, it was necessary to determine the parameters of the equivalent diagram. Considering the complexity and large volume of computation, the authors developed for this purpose, specific computational algorithms. For all these computational algorithms, computation programs have been drawn, being developed in the programming environment Mathcad Version 7.0, of own conception and which in principle can be used for any other similar motors that have different nominal data. It has also been highlighted that the starting point to establishing the opportunity of replacing of the analyzed asynchronous motors operating derated in steady state, is determining the actual load degree that is achieved through active power measurement for the considered regime.
Authors and Affiliations
Silvia-Maria Diga, Daniela Popescu, Nicolae Diga
How to Design a Passive Damped LCL Coupling Filter for an Active DC-Traction Substation
The attention in this paper is directed to the design of a passive damped LCL filter intended to connect the voltage source inverter of an active DC-traction substation to the AC-power supply. Based on the tasks to be fu...
Virtual Synchronoscope for Connecting Synchronous Generator on the Grid
In this paper is presented in a constructive and functional way an instrument that can be used at connecting synchronous generators at the grid supply that has a constant voltage and frequency. Actually it is abou...
Testing a Filtering and Regeneration System on a Recuperative Stand
The paper has three main objectives: the presen-tation of a laboratory model of a system for active filtering and regeneration (SISFREG) developed through an applied research collaborative project in the frame of Partner...
Improving the Shunt Active Power Filter Control Methods under Distorted and Unbalanced Grid Voltages
For a proper operation of the shunt active power filters, the current reference detection method must be robust. This means it must extract correctly the fundamental frequency even if the grid has distorted and unbala...
Dynamic State of Low Power Asynchronous Motors in Direct-on-Line Starting
The research opportunity is explained by the results obtained in modelling and simulation of asynchronous motors, in the purpose of increasing their technical and economic performances when they operate in dynamic states...