Variation of Performance of Refrigeration System at different Temperature

Abstract

  R143a and R152a) selected to replace R12 in a vapour compression refrigeration system were investigated experimentally and compared. The performance in term of coefficient of performance (COP), refrigerating capacity (RC), and compressor work (We) were evaluated for the investigated refrigerants at various evaporating and condensing temperatures. The system performance increases as the evaporating temperature increases, but reduces as the condensing temperature increases. The results obtained showed that the investigated refrigerants confirmed that R152a and R134a have approximately the same thermodynamic performances similar to R12 while deviation of R125 and R143a were very large. But the best performance was obtained from the used of R152a in the system. As a result, R152a could be used as a drop-in replacement for R134a in vapour compression refrigeration system. The COP of R152a obtained was higher than those of R12, R125, R134a, R143a. Also, R152a offers the best desirable environmental requirements; zero Ozone Depleting Potential (ODP) and very low Global Warming Potential (GWP).

Authors and Affiliations

Ankit Tiwari

Keywords

Related Articles

 Analysis of Effectiveness of ALERT Protocol against Wormhole Attack in MANETs

 Routing in MANETs is one of the challenging issues because it dynamically changes their topology over the time and hence requires an efficient routing protocol to communicate among the mobile nodes. There are seve...

Analysis of Regenerator for Reversed Stirling Cycle Which Various Geometry

Analysis of regenerator deals with assumptions made for analysis and different equation use to predict the performance of regenerator Problem and sample calculation deals with problem and calculation of various paramete...

 EVALUATE PERFORMANCE AND ANALYSIS CORROSION PRODUCTS FOR CARBON STEEL IN ACIDIC MEDIA

 The performance of carbon steel (C1010) has been evaluated in three acidic solutions: 1M HCL,1M H2SO4, 1M CH3COOH after immersion for 30 minutes and 300 minutes.The corrosion rate was determined by linear polariz...

ASSESSMENT OF WATER BALANCE OF A WATERSHED USING SWAT MODEL FOR WATER RESOURCES MANAGEMENT

An attempt has been made in this study to assess the hydrological behavior of the Kurumali sub basin of Karuvannur river basin using SWAT model and other geospatial technologies. All the thematic maps and attribute info...

 A State of Art Literature Review on Direct Displacement-Based Design for Seismic Structural Analysis

 Earthquakes are one of the most disastrous forces which cannot be stopped or prevented but their effects can be minimized with minimal causalities’ of lives and structural damages. Over the past decade, analysis a...

Download PDF file
  • EP ID EP89774
  • DOI -
  • Views 73
  • Downloads 0

How To Cite

Ankit Tiwari (30).  Variation of Performance of Refrigeration System at different Temperature. International Journal of Engineering Sciences & Research Technology, 3(7), 389-392. https://europub.co.uk/articles/-A-89774