Vicarious Calibration Data Screening Method Based on Variance of Surface Reflectance and Atmospheric Optical Depth Together with Cross Calibration

Abstract

 Vicarious calibration data screening method based on the measured atmospheric optical depth and the variance of the measured surface reflectance at the test sites is proposed. Reliability of the various calibration data has to be improved. In order to improve the reliability of the vicarious calibration data, some screenings have to be made. Through experimental study, it is found that vicarious calibration data screening would be better to apply with the measured atmospheric optical depth and variance of the measured surface reflectance due to the facts that thick atmospheric optical depth means that the atmosphere contains serious pollution sometime and that large deviation of the surface reflectance from the average means that the solar irradiance has an influence due to cirrus type of clouds. As the results of the screening, the uncertainty of vicarious calibration data from the approximated radiometric calibration coefficient is remarkably improved. Also, it is found that cross calibration uncertainty is poorer than that of vicarious calibration.

Authors and Affiliations

Kohei Arai

Keywords

Related Articles

Measures for Testing the Reactivity Property of a Software Agent

Agent technology is meant for developing complex distributed applications. Software agents are the key building blocks of a Multi-Agent System (MAS). Software agents are unique in its nature as it possesses certain disti...

 Prediction of New Student Numbers using Least Square Method

 STMIK BANJARBARU has acquired less number of new students for the last three years compared to the previous years. The numbers of new student acquisition are not always the same every year. The unstable number of n...

 Seamless Location Measuring System with Wifi Beacon Utilized and GPS Receiver based Systems in Both of Indoor and Outdoor Location Measurements

 A seamless location measuring system with WiFi beacon utilized and GPS receiver based systems in both of indoor and outdoor location measurements is proposed. Through the experiments in both of indoor and outdoor,...

The Research of the Relationship between Perceived Stress Level and Times of Vibration of Vocal Folds

Whether a syllable is perceived as stressed or not and whether the stress is strong or weak are hot issues in speech prosody research and speech recognition. A focus of the stress study is on the investigation of the aco...

 Sensitivity Analysis and Error Analysis of Reflectance Based Vicarious Calibration with Estimated Aerosol Refractive Index and Size Distribution Derived from Measured Solar Direct and Diffuse Irradiance as well as Measured Surface Reflectance

Sensitivity analysis and error of reflectance based vicarious calibration with estimated aerosol refractive index and size distribution derived from measured solar direct and diffuse irradiance as well as measured surfac...

Download PDF file
  • EP ID EP95674
  • DOI 10.14569/IJARAI.2015.041101
  • Views 166
  • Downloads 0

How To Cite

Kohei Arai (2015).  Vicarious Calibration Data Screening Method Based on Variance of Surface Reflectance and Atmospheric Optical Depth Together with Cross Calibration. International Journal of Advanced Research in Artificial Intelligence(IJARAI), 4(11), 1-7. https://europub.co.uk/articles/-A-95674