Neural Monitoring With CMOS Image Sensors

Journal Title: Basic and Clinical Neuroscience - Year 2015, Vol 9, Issue 3

Abstract

Implantable image sensors have several biomedical applications due to their miniature size, light weight, and low power consumption achieved through sub-micron standard CMOS (Complementary Metal Oxide Semiconductor) technologies. The main applications are in specific cell labeling, neural activity detection, and biomedical imaging. In this paper the recent research studies on implantable CMOS image sensors for neural activity monitoring of brain are being quantified and reviewed. Based on the results, the suitable implantable image sensors for brain neural monitoring should have high signal to noise ratio of above 60 dB, high dynamic range of near 88 dB and low power consumption than the safety threshold of 4W/cm2. Moreover, it is found out that the next generation of implantable imaging device trend should reduce the pixel size and power consumption of CMOS image sensors to increase spatial resolution of sample images.

Authors and Affiliations

Azar Yadegari, Mohammad Azim Karami, Mohammad Reza Daliri

Keywords

Related Articles

Characterization of Functional Effects of Two New Active Fractions Isolated From Scorpion Venom on Neuronal Ca2+ Spikes: A Possible Action on Ca2+-Dependent Dependent K+ Channels

Introduction: It is a long time that natural toxin research is conducted to unlock the medical potential of toxins. Although venoms-toxins cause pathophysiological conditions, they may be effective to treat several disea...

Generating the Visual Biofeedback Signals Applicable to Reduction of Wrist Spasticity: A Pilot Study on Stroke Patients

Introduction: Application of biofeedback techniques in rehabilitation has turned into an exciting research area during the recent decade. Providing an appropriate visual or auditory biofeedback signal is the most critica...

Management of Pituitary Adenomas: Mononostril Endoscopic Transsphenoidal Surgery

Introduction: The endoscopic transsphenoidal approach for pituitary adenomas and other sellar lesions is quickly becoming the procedure of choice in their surgical management. The most common approach is binostril three-...

The Effects of Counting the Stride Numbers on the Parkinsonian Gait: Suggesting a Possible Reason for Dual Task Interference

Introduction: Parkinson Disease (PD) is a degenerative and progressive disorder of the central nervous system. It results from degeneration of Substantia Nigra pars compacta (SNc) of the Basal Ganglia (BG). Gait disturba...

The Role of Protein Kinase B Signaling Pathway in Anti-cancer Effect of Rolipram on Glioblastoma Multiforme: An In Vitro Study

Introduction: The mechanism of putative cytotoxicity of 4-[3-(cyclopentyloxy)-4-methoxyphenyl]-2-pyrrolidone (rolipram), a specific phosphodiesterase-4 (PDE4) inhibitor, on glioblastoma multiforme (GBM) is almost unknown...

Download PDF file
  • EP ID EP455093
  • DOI 10.29252/nirp.bcn.9.3.227
  • Views 111
  • Downloads 0

How To Cite

Azar Yadegari, Mohammad Azim Karami, Mohammad Reza Daliri (2015). Neural Monitoring With CMOS Image Sensors. Basic and Clinical Neuroscience, 9(3), -. https://europub.co.uk/articles/-A-455093