Noise reduction of a water cooler equipment (chiller)

Journal Title: Romanian Journal of Acoustics and Vibration - Year 2011, Vol 8, Issue 1

Abstract

The chilling equipments of air conditioning installations – located on the flat roof – represent the sources of noise which can cause acoustical discomfort to the habitants from the neighborhood buildings. The dissertation presents the initials results of noise level measurements due to the water cooler equipment (chiller) mounted on the flat roof in 18 Jules Michelet Str. – Bucharest, technical principle solutions to decrease this noise and the final results. Was proposed a constructive solution on THE PROPAGATION PATH, a certain CHILLER SHIELDING by means of sandwich panels. By mounting this acoustical insulating panels was obtained a noise level reduction with 19 dB near the chiller, so the noise level propagated on the front of the building located in Magheru Bd. entered in the admissible limit of 50 dB(A), as specified in STAS 10009-88.

Authors and Affiliations

Mariana Cristina Stan, Ioana Mihaela Alexe

Keywords

Related Articles

Influence of the Constructive and Operational Features on the Natural Frequencies of the Centrifuges

This paper approaches a field of advanced fundamental research: the study of vibrations of industrial centrifuges considering the constructive and functional factors. It will be established special study model for centri...

A Study on Free Vibration of Visco-elastic Tapered Plate with Clamped Ends

A mathematical analysis is presented here to analyze the free vibration of visco-elastic isotropic rectangular plate. The main objectives of the study are to assist engineers and scientists in designing of structures whi...

Linear Motion Profile Generation using a Danaher Thomson Actuator with Ball Screw Drive

A Danaher Thomson linear actuator with ball screw drive is used here to generate vibrations in the 1-3 Hz frequency range. More precisely, the linear motion profile corresponding to the vertical displacements induced und...

Noise Attenuation by Using Special Shape Robber Panel

Within the last few years, concern about the protection of the environment has grown rapidly as it has become generally recognized that the steady rise in pollution of all kinds cannot be allowed to continue indefinitely...

Assessment of Dissipated Energy to Harmonic Cycles of Displacement for Visco-Elastic Elastomeric Anti-Seismic Insulators

The paper presents some results of the research carried out to highlight the dissipation capacity of the elastomeric systems to harmonic deformations due to the kinematic excitations of the exterior harmonic displacement...

Download PDF file
  • EP ID EP124541
  • DOI -
  • Views 67
  • Downloads 0

How To Cite

Mariana Cristina Stan, Ioana Mihaela Alexe (2011). Noise reduction of a water cooler equipment (chiller). Romanian Journal of Acoustics and Vibration, 8(1), 73-74. https://europub.co.uk/articles/-A-124541