NUMERICAL ANALYSIS OF PREFABRICATED STEEL-CONCRETE COMPOSITE FLOOR IN TYPICAL LIPSK BUILDING

Journal Title: Civil and Environmental Engineering Reports - Year 2017, Vol 4, Issue 27

Abstract

The aim of the work was to perform numerical analysis of a steel-concrete composite floor located in a LIPSK type building. A numerical model of the analytically designed floor was performed. The floor was in a six-storey, retail and service building. The thickness of a prefabricated slab was 100 mm. The two-row, crisscrossed reinforcement of the slab was made from φ16 mm rods with a spacing of 150 x 200 mm. The span of the beams made of steel IPE 160 profiles was 6.00 m and they were spaced every 1.20 m. The steel-concrete composite was obtained using 80x16 Nelson fasteners. The numerical analysis was carried out using the ADINA System based on the Finite Element Method. The stresses and strains in the steel and concrete elements, the distribution of the forces in the reinforcement bars and cracking in concrete were evaluated. The FEM model was made from 3D-solid finite elements (IPE profile and concrete slab) and truss elements (reinforcement bars). The adopted steel material model takes into consideration the plastic state, while the adopted concrete material model takes into account material cracks.

Authors and Affiliations

Piotr LACKI, Przemysław KASZA, Anna DERLATKA

Keywords

Related Articles

Statistical analysis of nitrogen in the soil of constructed wetland with horizontal sub-surface flow

The removal of nitrogen compounds in constructed wetlands depends on various physical, chemical and biomechanical factors as well as on conditions of the environment. The paper presents the results of a statistical analy...

The tourist infrastructure of the waterway in a segment of the lower Warta River

The Polish segment of the E70 International Waterway comprises an area stretching from the western border of Poland with Germany (the estuary of the Warta River) to Żuławy Wiślane (including the area surrounding the Poli...

CHEMICAL SOIL DEGRADATION IN THE AREA OF THE GŁOGÓW COPPER SMELTER PROTECTIVE FOREST

Earth surface is under the continous influence of the environmental factors – both natural and anthropogenic. The significant impact on the environment can be noted in areas adjacent to the metal industry plants, in a co...

Flood risk of lower silesia voivodship

Floods are natural events of a random nature that cause damage in property, agriculture, and industry. Floods in the upper and middle Odra basin, particularly on a large scale, are characterized by their specificity of a...

TEST OF IMPACT OF VIBRATIONS FREQUENCY ON MEAN ERRORS OF THE PRECISE HEIGHT DIFFERENCES MEASUREMENT WITH ANALOGUE AUTOMATIC LEVELLER NI002

The article describes the results of tests carried out to determine the measurable effect of vibrations on the accuracy of measurements with an automatic precise leveller. It contains specification of the research statio...

Download PDF file
  • EP ID EP270308
  • DOI 10.1515/ceer-2017-0049
  • Views 62
  • Downloads 0

How To Cite

Piotr LACKI, Przemysław KASZA, Anna DERLATKA (2017). NUMERICAL ANALYSIS OF PREFABRICATED STEEL-CONCRETE COMPOSITE FLOOR IN TYPICAL LIPSK BUILDING. Civil and Environmental Engineering Reports, 4(27), 43-53. https://europub.co.uk/articles/-A-270308