NUMERICAL INVESTIGATION OF STRESS GENERATED IN HIGH PRESSURE HEAT EXCHANGER

Abstract

Heat Exchangers are used to transfer heat effectively from one medium to another medium. There are several aspects to study the performance of heat exchanger. This paper is concerned with thermo-mechanical issues i.e. thermal expansion due to high temperature and high pressure conditions of U-tube heat exchanger. Tubesheet is very complex part of heat exchanger which expands at high temperature. Due to high temperature difference between shell side and channel side fluids thermal stress are generated in the tubesheet which effects on the performance of the heat exchanger. 3D FEA model was modeled in ANSYS® to study the thermo-mechanical effect on heat exchanger. Mesh sensitivity analysis was performed to obtain precise results and optimum mesh size. Static structural stress analysis was performed under for two conditions, at first only mechanical loading was studied and secondly mechanical and thermal loading effects were studied. In steady state condition, tubesheet thickness was optimized using 3D parametric model in FEA. The results of the elastic stress analysis were evaluated as per ASME Section VII DIV-2 code limits. It is found that with the optimization  design, the tubesheet thickness could be reduced by 20-25% without affecting the safety of the heat exchanger wthin the allowable limits.

Authors and Affiliations

Sandeep S. Samane

Keywords

Related Articles

 A Novel FP-Tree Algorithm for Large XML Data Mining

 The goal of data mining is to extract or mine" knowledge from popular for representing semi structured data and a standard for data exchange over the web. Mining XML data from the web is becoming increasingly imp...

 Investigations on the Penetration Properties of Electromagnetic Waves in Biological Media

 Interaction of Electromagnetic radiation with the human body is a complex function of numerous parameters. The electromagnetic radiation is characterized by its frequency, intensity of electric and magnetic fields...

 A CARBON DRAIN PRESSURE VESSEL & NOZZLE STRESS ANALYSIS

 Due to functional requirement, Nozzle are require for pressure vessel. If these nozzle present on peak of the dishend do not disturb the symmetry of the vessel. However sometimes process requires that nozzles to be...

A REVIEW OF LITERATURE ON THERMAL DESIGN OF FORCED DRAFT COUNTER TO CROSS FLOW AIR COOLED HEAT EXCHANGER

Heat exchangers are equipment that transfers heat from one medium to another. An air cooled heat exchanger, or ACHE, is simply a pressure vessel which cools a circulating fluid within finned tubes by forcing ambient air...

 FPGA Implementation of Digital PI Filter and Reset Loop Controller for DPLL

 This paper presents implementation of Digital PI (Proportional- Integral) filter on FPGA and reset loop filter for Digital Phase Locked Loops (DPLL). The PI filter is derived from control theory, known as “proport...

Download PDF file
  • EP ID EP128376
  • DOI 10.5281/zenodo.56006
  • Views 42
  • Downloads 0

How To Cite

Sandeep S. Samane (30). NUMERICAL INVESTIGATION OF STRESS GENERATED IN HIGH PRESSURE HEAT EXCHANGER. International Journal of Engineering Sciences & Research Technology, 5(6), 771-778. https://europub.co.uk/articles/-A-128376