Numerical Investigation of the Physical Properties Effect on the Thermal Performance of a Vertical Geothermal Heat Exchanger
Journal Title: Engineering, Technology & Applied Science Research - Year 2018, Vol 8, Issue 2
Abstract
Low-temperature geothermal energy is a promising technique for heating and cooling residential and commercial premises, especially since it is one of the green energy solutions that respect the environment. The principle of this technique is based on thermal exchange between the heat pump and the basement using a vertically buried heat exchanger. This is usually made of a U-shaped tube inserted vertically in a borehole made in the ground and filled with a filler material. The purpose of the present study is to vary the different construction materials of the U-tube, the filling material and the soil, in order to obtain the most energy-efficient parameters. The evolution of temperature and heat flux as a function of time has been highlighted for different combinations. Knowing that an experimental study requires a considerable monetary fund, the present model has been validated using previously literature results. Recommendations on the choice of different materials of the geothermal heat exchanger are proclaimed at the end of this work.
Authors and Affiliations
M. Benyoub, B. Aour, B. Bouhacina, K. Sadek
Prediction of Springback in the Air Bending Process Using a Kriging Metamodel
This paper addresses the use of the kriging approach to predict the springback in the air bending process. The materials and the geometrical parameters, which significantly affect the springback, were considered as inpu...
Thoughts on the Possibility of Damage of High-Voltage Electrical Insulation below the So-Called Inception Voltage: Simulation under a Superposition of AC and DC Voltage – Part III
In a previous work, a typical case is studied, where a solid sheet insulation contains a void under DC or AC voltage. In the present paper, to study the charging phenomenon in HVDC valve windings and cables, a more compl...
Optimal Power Factor for the Reactive Load of Small Hydro Power Plants
This article explores the operation algorithm of an excitation regulator of synchronous generators of small Hydro Power Plants (HPPs). The aim is to provide optimum economic parameters, consistent with the dynamically ch...
FahamecV1:A Low Cost Automated Metaphase Detection System
In this study, FahamecV1 is introduced and investigated as a low cost and high accuracy solution for metaphase detection. Chromosome analysis is performed at the metaphase stage and high accuracy and automated detection...
Numerical Study of the Thermal Behavior of a Composite Phase Change Material (PCM) Room
In this study, thermal performance of building walls integrated with phase change materials (PCM) was evaluated in terms of indoor temperature reduction and heat transfer time delay. PCM was incorporated as thin layer pl...