Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study

Journal Title: Balkan Medical Journal - Year 2017, Vol 34, Issue 5

Abstract

Background: Proximal femoral fracture rates are increasing due to osteoporosis and traffic accidents. Proximal femoral nails are routinely used in the treatment of these fractures in the proximal femur. Aims: To compare various combinations and to determine the ideal proximal lag screw position in pertrochanteric fractures (Arbeitsgemeinschaft für Osteosynthesefragen classification 31-A1) of the femur by using optimized finite element analysis. Study Design: Biomechanical study. Methods: Computed tomography images of patients" right femurs were processed with Mimics. Afterwards a solid femur model was created with SolidWorks 2015 and transferred to ANSYS Workbench 16.0 for response surface optimization analysis which was carried out according to anterior-posterior (-10°<anterior-posterior<10°), inferior-superior (-6°<inferior-superior<7°) and tip-apex distance (10 mm<tip-apex distance<30 mm) proximal lag screw positions in the fracture region. The optimum position of the proximal lag screw was determined based on the von Mises stress values occurring on the fracture line. Initial analysis of the system was realized under the surgeon"s normal positioning conditions (anterior-posterior, inferior-superior=0°; tip-apex distance=12 mm). Results: The maximum and minimum (compression) von Mises stresses were found to be 438 MPa and 0.003 MPa, respectively, and risky stresses for the system occurred in the regions where the proximal lag screw passes through the proximal femoral nail hole, the small diameter portion of stem joints with a large diameter and lag screw mounts to the stem. The most suitable position of the proximal lag screw was found at the middle position of the tip-apex distance (20 mm) and femoral neck (anterior-posterior, inferior-superior=0°), according to von Mises compression stress values occurring on the fracture line. Conclusion: In our study, we couldn"t find any correlation between proximal lag screw movement and tip-apex distance on stresses of the fracture surfaces, but the proximal lag screw position in the inferior (inferior-superior<0)-superior (inferior-superior>0) and posterior-anterior directions of the femur neck significantly increased these stresses. The most suitable position of the proximal lag screw was confirmed as the middle of the femoral neck by using optimized finite element analysis.

Authors and Affiliations

Mehmet Nuri Konya, Özgür Verim

Keywords

Related Articles

O6-methylguanine-DNA Methyltransferase Promoter Methylation in Patients with Rectal Adenocarcinoma After Chemoradiotherapy Treatment: Clinical Implications

Aims: To analyze the clinical relevance of O6-methylguanine-DNA methyltransferase in rectal adenocarcinoma treated with chemoradiotherapy followed by surgery. Methods: Tissue samples from 29 rectal adenocarcinoma patient...

Caffeine Increases Apolipoprotein A-1 and Paraoxonase-1 but not Paraoxonase-3 Protein Levels in Human-Derived Liver (HepG2) Cells

Background: Apolipoprotein A-1, paraoxonase-1 and paraoxonase-3 are antioxidant and anti-atherosclerotic structural high-density lipoprotein proteins that are mainly synthesized by the liver. No study has ever been perfo...

Download PDF file
  • EP ID EP380506
  • DOI 10.4274/balkanmedj.2016.0732
  • Views 59
  • Downloads 0

How To Cite

Mehmet Nuri Konya, Özgür Verim (2017). Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study. Balkan Medical Journal, 34(5), 425-431. https://europub.co.uk/articles/-A-380506