Observational Study Comparing the Measurement of Abdominal Aortic Aneurysm (AAA) Diameter in Different Morphology with Ultrasound and CT Scan

Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 6

Abstract

ABSTRACT Introduction: Ultrasound (US) is the gold standard imaging modality used to measure the diameter of Abdominal Aortic Aneurysms (AAA), and it is used in the surveillance of AAAs. The use of Computed Tomography (CT) has now become widespread. There has always been disagreement between CT and US, which significantly affects management decisions. Aim: To examine the agreement between US and CT in measuring aortic diameter. Furthermore, it was used to investigate if size discrepancy between US and CT increases as the AAA size increases. Materials and Methods: This was a single centre retrospective observational study. It included 212 patients, with infra-renal aorta of diameters ≥3 cm, who had undergone an US of the aorta and a CT aortogram within 90 days of each other. US-measured maximum Antero-Posterior (AP) aortic diameter and CT-measured maximum aortic diameter were considered. Statistical analysis was performed using Bland-Altman plot, paired t-test and Pearson’s correlation. Results: There was a significant disagreement between measurements on CT and US. The mean US measured AP diameter was 5.4 cm (SD1.05), whereas the mean maximum measured aortic diameter on CT was 5.7 cm (SD1.13) (p<0.001). We did not find any disagreement between US and CT as the size of the AAA increased, with significant but weak correlation (cc 0.27) (p<0.001). Conclusion: Our results demonstrate that US, on average, underestimates the size of AAAs by 0.3 cm when compared to CT. We failed to demonstrate correlation between increasing aneurysm size and increasing disagreement between CT and US.

Authors and Affiliations

Ahmed Shalan, James Forsyth, Andrew Thompson

Keywords

Related Articles

Effect of Intracuff Inflation with Alkalinised Lignocaine, Saline and Air on Early Postoperative Airway Morbidity-A Randomised Control Trial

ABSTRACT Introduction: Endotracheal intubation is the gold standard of airway management, and usage of the cuffed Endotracheal Tube (ETT) is routine clinical practice. The ETT provides adequate ventilation and reduces as...

Recurrent Longitudinally Extensive Myelitis and Aquaporin-4 Seronegativity – The Expanding Spectrum of Neuromyelitis Optica

Neuromyelitis Optica Spectrum Disorder (NMOSD) is a recently proposed unifying term for Neuromyelitis Optica (NMO), also known as Devic's disease and related syndromes. It is a relapsing inflammatory demyelinating diseas...

Features of the Spatial Perception in Persons with Mental Disorders

ABSTRACT Many of the various mental pathologies afflicting mankind in modern society require more detailed research. One of the directions requiring additional studying is that of spatial perception in mental patients. T...

Anti-Atherosclerotic Potential of Aqueous Extract of Cinnamomum zeylanicum Bark against Glucocorticoid Induced Atherosclerosis in Wistar Rats

Introduction: Atherosclerosis is one of the major causes of disability of blood vessels which can result in development of many cardiovascular disorders. There is a strong association between atherosclerosis and insulin...

Download PDF file
  • EP ID EP524360
  • DOI 10.7860/JCDR/2018/35413.11665
  • Views 99
  • Downloads 0

How To Cite

Ahmed Shalan, James Forsyth, Andrew Thompson (2018). Observational Study Comparing the Measurement of Abdominal Aortic Aneurysm (AAA) Diameter in Different Morphology with Ultrasound and CT Scan. Journal of Clinical and Diagnostic Research, 12(6), 5-7. https://europub.co.uk/articles/-A-524360