Occupational Exposure of Train Drivers to Static and Extremely Low Frequency Magnetic Fields in Tehran Subway
Journal Title: UNKNOWN - Year 2017, Vol 9, Issue 4
Abstract
Background: Electrification of transport systems currently deserves top priority in Iran. Such systems generate a magnetic field in static or extremely low frequency ranges. Therefore, train drivers may be exposed to these fields occupationally. Objectives: The current study aimed to measure the intensity of static magnetic field (SMF) and extremely low frequency magnetic fields (ELF-MF) in the subway trains of Tehran City in different train types and situations to show drivers’ exposure to SMF and ELF-MF. Methods: Two AC and DC trains were randomly selected from lines 1 and 2, one AC train from line 4, and two ACi trains from line 5. The SMF and ELF-MF levels were measured based on BS EN 50500:2008 and recommendations in other studies using TES-1394 (ELF-MF meter) and HI-3550 (SMF meter). Ceiling values of ELF-MF and SMF were used for assessment of train driver’s exposure. One-way ANOVA, with Tukey post hoc test, and independent sample T-test were used for data analysis. Results: Maximum SMF and ELF-MF exposures were 0.52 mT (at DC trains- in trip situation) and 7.90 µT (at ACi trains- in trip situation), respectively, and the minimum exposures to SMF and ELF-MF were measured among the drivers of ACi (< 0.1 mT- in all situations) and AC trains (0.08 µT- in acceleration situation), respectively. Conclusions: As the obtained results suggest, in none of the situations, exposure of train drivers to ELF-MF and SMF exceeded the threshold limits recommended by ACGIH. However, the effects of these fields should not be ignored because different studies have reported adverse health consequences of these fields.
Authors and Affiliations
Hamed Jalilian, Kamran Najafi, Mohammad Reza Monazzam, Yahya Khosravi, Jamshid Jamali
Identification and Evaluation of Human Errors in the Medication Process Using the Extended CREAM Technique
Background: Medication process is a powerful instrument for curing patients. Obeying the commands of this process has an important role in the treatment and provision of care to patients. Medication error, as a complicat...
Determining the Correlation Between Three and Seven Day Records of Fluids Consumption to Determine an Appropriate Method for Estimating the Amount and Type of Fluids Intake in Adults
Background: Different methods are used for adequate fluid intake assessment, while there is no standard method for adequate fluid intake assessment. Objectives: The current pilot study aimed to evaluate the amount, type...
The Relationship Between Physical Work Capacity and Asthma Disease
Background: The measurement of physical work capacity (PWC) is important to create the physiological balance between work and worker. The results of some studies showed a relationship between maximum amount of oxygen con...
Assessment and Design of Illumination in a Steel Manufacturing Company in Ahvaz, Iran
Background: Illumination is a physical factor in workspaces. This factor is an important risk factor for vision health, employees comfort, preventing accidents etc. and should be standardized. Objectives: The current st...
Analyzing Human Error in Municipal Water Systems Using Systematic Human Error Reduction and Prediction Approach SHERPA Method
Background: The perception that water treatment and supply systems are not safe against accident and human errors as well as disease outbreaks is growing. Many major events around the world have been attributed to human...