ОЦІНКА МЕТОДИЧНОЇ ПОХИБКИ ТЕРМОЕЛЕКТРИЧНОГО ПЕРЕТВОРЮВАЧА З КЕРОВАНИМ ПРОФІЛЕМ ТЕМПЕРАТУРНОГО ПОЛЯ

Abstract

The method of a methodical error evaluation for the thermocouple with a controlled temperature profile caused by a thermal flow to/from the hot junction of the thermocouple is presented in this paper. This methodical error is caused by a deviation of the real conversion characteristics of main thermocouple and thermocouples of a control system from their nominal conversion characteristics. Its evaluation is considered as a limit of temperature variation of the hot junction of main thermocouple in the condition of stepping changing of the conversion characteristic of thermocouples.

Authors and Affiliations

Орест Кочан, Тарас Демків, Анатолій Саченко

Keywords

Related Articles

СЕРТИФІКАЦІЯ ПРОФЕСІЙНОЇ КОМПЕТЕНТНОСТІ ПЕРСОНАЛУ

Certification of personnel is analysed as guarantor of competence of specialists, confirmation of their professionalism.

РИЗИКИ, ЩО СУПРОВОДЖУЮТЬ ГОСПОДАРСЬКУ ДІЯЛЬНІСТЬ - СУТНІСТЬ, КЛАСИФІКАЦІЯ І ПІДХОДИ ДО ОЦІНЮВАННЯ

The content of the term “risk” and appropriate adjacent notions are analyzed, their unambiguous interpretation for the needs of reference the economy subjects to the risk groups which would include the probability of neg...

ПІДВИЩЕННЯ РІВНЯ ТЕХНОГЕННОЇ БЕЗПЕКИ ПРОЦЕСІВ СПАЛЮВАННЯ НЕКОНДИЦІЙНОГО ПАЛИВА

An influence of some admixtures based on calcium carbonate and hydroxide on physico-chemical, caloric and some other properties of the coal-water fuel has been investigated. Some specific regularities have been found and...

ОТРИМАННЯ КОЕФІЦІЄНТІВ ВАГОМОСТІ ДЛЯ КІЛЬКІСНОЇ ОЦІНКИ ЯКОСТІ ПРОДУКЦІЇ ЗА СКЛАДОВИМИ НЕВИЗНАЧЕНОСТІ ОЦІНЮВАННЯ

The way of weight coefficient determination based on the considering the specific component of measurement result accuracy, whose quantitative estimation reflects the inhomogeneity of research object and instability of i...

РЕАЛІЗАЦІЯ МІТКОВОГО ПЕРЕТВОРЮВАЧА ВИТРАТИ ГАЗУ В СКЛАДІ ІНФОРМАЦІЙНО- ВИМІРЮВАЛЬНОГО КАНАЛУ ЕТАЛОННОЇ ДЗВОНОВОЇ УСТАНОВКИ “ТЕМПО-3”

In the article the information-measuring channel implementation of threshold sensitivity control on the primary transducer of the label-type element is proposed. The experiments results are presented which testify to the...

Download PDF file
  • EP ID EP192633
  • DOI -
  • Views 62
  • Downloads 0

How To Cite

Орест Кочан, Тарас Демків, Анатолій Саченко (2008). ОЦІНКА МЕТОДИЧНОЇ ПОХИБКИ ТЕРМОЕЛЕКТРИЧНОГО ПЕРЕТВОРЮВАЧА З КЕРОВАНИМ ПРОФІЛЕМ ТЕМПЕРАТУРНОГО ПОЛЯ. Вимірювальна техніка та метрологія, 1(69), 79-84. https://europub.co.uk/articles/-A-192633