Ocular response analyzer (ORA) derived parameters compared to Sirius corneal topography in analyzing corneal pathology
Journal Title: Indian Journal of Clinical and Experimental Ophthalmology - Year 2016, Vol 2, Issue 3
Abstract
Purpose: To evaluate the ability of Ocular Response Analyzer (ORA) to differentiate between normal and abnormal corneas as compared to Sirius corneal topography. Methods: This retrospective study included 302 eyes of 151 patients. All patients underwent evaluation with ORA and Sirius corneal topography. Parameters included disease classification results on both instruments (device software classification), Surface asymmetry index (SAI) on Sirius, Corneal Hysteresis (CH), Corneal Resistant Factor (CRF), Keratoconus Match Index (KMI), Goldmann-correlated intraocular pressure (IOPg), Corneal compensated intraocular pressure (IOPcc) and waveform score (WS) on ORA. Results: On Sirius, 198 eyes (65.6%) were classified as normal. On ORA, 121 eyes (40.1%) were documented as normal. Overall, 105 eyes (34.8%) were classified as normal and 88 eyes (29.1%) with non-normal classification on both Sirius and ORA. Of the 198 eyes classified as normal on Sirius, 53% were classified as normal, 39% as suspect and 8% as mild keratoconus on ORA (47% non-normal). Of the 121 eyes classified as normal on ORA, 87% were classified as normal, 6% as suspect, and 2% as keratoconus compatible on Sirius (13% non-normal). Four percent of the eyes classified as keratoconus compatible on Sirius were classified as normal on ORA. There was a significant difference when comparing normal and non-normal classifications between ORA and Sirius (p < 0.001) with poor agreement (Kappa=0.32). When including only normal and Keratoconus eyes in the analysis, good agreement was found between the two machines (Kappa=0.75). Conclusion: According to our results there seems to be a significant difference between ORA and Sirius in their ability to differentiate between normal and non-normal eyes. As such, we recommend that these devices not to be used interchangeably for assessing patients prior to refractive surgery.
Authors and Affiliations
Tania Ayad Baban, Fady Kamal Sammouh, Haitham Muhidine El Ballouz, Elias Lutfalla Warrak
A comprehensive study to evaluate the safety and efficacy of Nd: YAG laser capsulotomy in the management of posterior capsular opacification in a rural environment
Objective: To evaluate the safety and the efficacy of Neodymium Yttrium Aluminium Garnet (Nd: YAG) laser capsulotomy in the management of posterior capsular opacification in a rural population. Materials and Method: An i...
Prevalence of diabetic retinopathy in urban and rural population in Eastern Uttar Pradesh
Introduction: Diabetes mellitus (DM) is an important public health concern, globally there is a rising trend in the prevalence of DM due to many factors such as aging, urbanization and increasing obesity and physical ina...
Association of severity of diabetic retinopathy with comorbidities in Type 2 diabetes mellitus
Introduction: Diabetes mellitus is emerging as a multisystem disease culminating in various complications especially to the ocular system if not treated at the earliest. The role of various comorbidities in aggravating t...
Treatment of advanced white cataracts with manual small incision cataract surgery: a prospective study
Purpose: To assess the complications and visual outcome of manual small incision cataract surgery in the treatment of advanced white cataracts. Methods: This prospective study included 50 eyes of 50 consecutive patients...
Comparative study of efficacy of topical dexamethasone 0.1% with difluprednate 0.05% in post-operative small incision cataract surgery
Introduction Postoperative ocular inflammation is a common occurrence following cataract surgery Corticosteroids have been used to treat ocular inflammation however they carry a risk of side effects particularly an incre...