On PIXE Analysis of Medical Samples: Thalassemia & Wilson

Journal Title: JOURNAL OF ADVANCES IN PHYSICS - Year 2017, Vol 13, Issue 9

Abstract

The contents of six elements (Cl, K, Ca, Fe, Cu, Zn) for medical samples of 30 patients (15 with wilson's disease and 15 with Thalassemia's disease) were determined by proton induced X-ray emission (PIXE) method. In analysis of these samples, abnormal contents of Cu for wilson's disease and of Fe for Thalassemia's disease were observed which shows that for these cases the situation of patient's illness is very serious.

Authors and Affiliations

Amir Pishkoo

Keywords

Related Articles

MicroVolt Variations of The Human Brain (Quantitative Electroencephalography) Display Differential Torque Effects During West-East versus North-South Orientation in the Geomagnetic Field

The human brain was assumed to be an elliptical electric dipole. Repeated quantitative electroencephalographic measurements over several weeks were completed for a single subject who sat in either a magnetic eastward or...

THE NOTHING THAT REALLY IS!

The denial of the existence of contradiction is at the root of all idealism in epistemology and the cause for alienations.This alienation has become a hindrance for the understanding of the nature and the historical evol...

Molecular Spectroscopic Characterization and Electronic Structure Analysis of N- benzylaniline- A DFT Approach

The FT-IR and FT-Raman spectra of N-benzylaniline[NBZA]  have been analysed in the region 4000-450cm-1 and 4000-50cm-1respectively. The geometrical structure, harmonic vibrational  frequency, infrared intensity...

ZnS/Cu2ZnSnS4/CdTe/In Thin Film Structure for Solar Cells

A solar cell with glass/ITO/ZnS/Cu2ZnSnS4/CdTe/In structure has been fabricated using all-electrodeposited ZnS, Cu2ZnSnS4 and CdTe thin films. The three semiconductor layers were electrodeposited using a two-electrode sy...

Characterization of high quality carbon nanotubes synthesized via Aerosol -CVD

new Aerosol assisted CVD method of synthesizinglarge amount ofhigh quality carbon nanotubes (CNTs) with good structural parameters has been developed. We report the optimization of the process by experimental variables o...

Download PDF file
  • EP ID EP653448
  • DOI 10.24297/jap.v13i9.6335
  • Views 47
  • Downloads 0

How To Cite

Amir Pishkoo (2017). On PIXE Analysis of Medical Samples: Thalassemia & Wilson. JOURNAL OF ADVANCES IN PHYSICS, 13(9), 5105-5110. https://europub.co.uk/articles/-A-653448