Operative treatment of bone fracture with Kirschner wires - young cat case

Journal Title: Engineering of Biomaterials / Inżynieria Biomateriałów - Year 2017, Vol 20, Issue 141

Abstract

This case study shows a cross pin technique of treating an epiphyseal fracture using the Kirschner wires in the case of a ten-month old European cat. The radiological diagnosis was performed both before and after the implantation. The radiological diagnosis proved a few day epiphyseal exfoliation of the left distal radius and the epiphyseal fracture of the distal ulna. The cat was sedated and subjected to general anesthesia. An operation was performed to stabilize the radius with the Kirschner wires, using the cross pin technique going through the distal epiphyseal and the cortical bone of the radius. The limb was immobilised for 4 weeks. After one month the reoperation was performed to remove the Kirschner wires. The microstructure of the implanted wires was observed using the scanning electron microscope equipped with X-ray energy dispersion spectrometer (SEM-EDS). The chemical analysis in the area around the operated tissue was performed. The radiological analysis showed the proper bone adjustment and its complete healing after 4 weeks after the surgery. The SEM-EDS analysis revealed no corrosion of the wire and lack of nickel in the tissues surrounding the implants. Throughout the rehabilitation the applied stabilization assured the cat the ordinary living conditions without noticeable discomfort.

Authors and Affiliations

M. Ziąbka, P. Derkowski

Keywords

Related Articles

Material and corrosion studies of conventional Co-Cr-Mo-W alloys for frame construction casts in dental prosthetics

The basic characteristics of skeletal prosthetic materials used in dentistry are: biotolerance with tissues and body fluids, as well as high pitting and crevice corrosion resistance. Also important are such characteristi...

Graphene oxide and green-synthesized reduced graphene oxide in chitosanbased nanocomposites

The first part of the paper concerns synthesis and characterization of two types of nanomaterials: graphene oxide (GO) prepared by modified Marcano method and reduced graphene oxide (rGO) synthesized using green reductan...

Charakterystyka mechaniczna wielofunkcyjnej resorbowalnej płytki kompozytowej do zespoleń kostnych

W artykule przedstawiono badania mechaniczne prototypowego wszczepu do zespoleń kostnych w postaci resorbowalnej wielofunkcyjnej czterootworowej płytki w kształcie litery I. Testy dotyczyły gotowych implantów w symulowan...

Kofeina jako czynnik modyfikujący hydrożele akrylowe

Hydrożele są materiałami zbudowanymi z łańcuchów polimerowych, które tworzą trójwymiarową i usieciowaną strukturę. Mają one bardzo dużą zdolność do pochłaniania wody, stąd też bardzo często są nazywane superabsorbentami....

Badanie działania antybakteryjnego kompozytów na bazie poli(L-laktydu) przeznaczonych na biodegradowalne gwoździe śródszpikowe

Implantacja gwoździ śródszpikowych wiąże się z ryzykiem wystąpienia poważnej infekcji kości spowodowanej zakażeniem bakteryjnym. Tradycyjna antybiotykoterapia w tym przypadku ma wiele ograniczeń. Rozwiązaniem tego proble...

Download PDF file
  • EP ID EP538705
  • DOI -
  • Views 35
  • Downloads 0

How To Cite

M. Ziąbka, P. Derkowski (2017). Operative treatment of bone fracture with Kirschner wires - young cat case. Engineering of Biomaterials / Inżynieria Biomateriałów, 20(141), 20-27. https://europub.co.uk/articles/-A-538705