“Optimization of Heat Gain by Air Exchange through the Window of Cold Storage Using S/N Ratio and ANOVA Analysis”

Abstract

Energy is at scarcity, crisis of energy is leading towards a world where growth might come to an absolute hold and optimizing the processes might give a way out to save energy for future generations and give some positive way out. In this situation if the maximum heat energy (Q) is absorbed by the evaporator inside the cold room through convective heat transfer process in terms of –heat transfer due to convection and heat transfer due to condensation and also heat enter in the cold store due to air exchange through the windows more energy has to be wasted to maintain the evaporator space at the desired temperature range of 2-6 degree centigrade. In this paper we have tried to optimize the heat gain by the air exchange through the windows of cold storage in the evaporator space using regression analysis. Temperature difference (dT), Height of cold store Window (H) and Relative Humidity (RH) are the basic variable and three ranges are taken each of them in the model development. Graphical interpretations from the model justify the reality through S/N ratio calculation and ANOVA analysis.

Authors and Affiliations

Dr. Nimai Mukhopadhyay, Aniket Deb Roy

Keywords

Related Articles

Alarm System Implementation on Field Programmable Gate Array

In recent times, Field Programmable Gate Arrays have wide applications in market due to its advantage of having programmable interconnects. Alarm-system is the best solution to overcome house intrusion. The effective Ala...

On the Mn-In-Ni Diatoms: Electronic Properties Depending on Spin Multiplicity

In this study, Ni, Mn and In atoms formed by different combinations of diatoms due to the spin multiplicity of electronic structure characteristics have been investigated. Calculations have been performed by Density Func...

A 0.6-V 2-nA CMOS Current Reference Circuit

This paper proposes a 0.6-V current reference circuit for use in ultra-low-power applications. In a conventional resistorlessbeta-multiplier current reference circuit, a MOSFET that operates in the strong inversion and t...

Doubly Fed Induction Generator Based WECS With The Double Trap LLCL Filter For Harmonics Mitigation

The wind energy conversion system integrated with a doubly fed induction generator. The PWM based back-toback power converters produced harmonic and as well as the non-linear loads are also a contributor of harmonics. Fi...

Study of MHD Nanofluid over a Moving Surface with Thermal Radiation

This paper consists of MHD and nano effect on the flow over a moving surface in presence of thermal radiation. The effect of thermal radiation on velocity and temperature of the fluid are studied by using Rossland diffus...

Download PDF file
  • EP ID EP390994
  • DOI 10.9790/9622-0704047278.
  • Views 126
  • Downloads 0

How To Cite

Dr. Nimai Mukhopadhyay, Aniket Deb Roy (2017). “Optimization of Heat Gain by Air Exchange through the Window of Cold Storage Using S/N Ratio and ANOVA Analysis”. International Journal of engineering Research and Applications, 7(4), 72-78. https://europub.co.uk/articles/-A-390994