Optimization of Polyethylene Inserts Design Geometry of Total Knee Prosthesis

Journal Title: International Scientific and Vocational Studies Journal - Year 2018, Vol 2, Issue 2

Abstract

Knee prostheses are produced from biomaterials which are compatible with human body as a result of damage of cartilage tissue due to various health problems. These prostheses consist of polyethylene parts between the Tibial Component and the femoral component of the femur. Polyethylene insert is used to reduce wear mechanisms between both materials. In this study, design library design parameters required for obtaining a polyethylene insert design were determined. These design parameters were modeled in the Solid Works Computer Aided Design (CAD) Program according to the L27 experiment design for each design parameter S / N ratios for three different levels using the Taguchi Method. For the safety coefficient analysis of each design, maximum forces in the literature were determined and implemented in Ansys Computer Aided Engineering (CAE) Program. According to the results of this analysis, maximum stress, weight and safety coefficient changes of each design geometry were determined. S / N ratios and% effects of each design parameter were determined by applying Taguchi and Variance Analysis. According to these results, the design is optimized by selecting the levels of each design parameter for the minimum weight and maximum safety factor. On the other hand, stress change graphs were obtained in different sections of the design. In the literature, for the first time, the design geometry of the polyethylene part was modeled by parametric design and optimum design was obtained.

Authors and Affiliations

Burak Öztürk, Levent Uğur, Fehmi Erzincanlı, Özkan Küçük

Keywords

Related Articles

Complementary Coded Waveforms Sets in Marine Radar Application

Complementary coded waveform and mismatched filter pairs sets are used. On the contrary with Golays matched waveform filter pair the mismatched waveform filter pair does exist for all N (number pulses in waveform). Using...

Optimization of Polyethylene Inserts Design Geometry of Total Knee Prosthesis

Knee prostheses are produced from biomaterials which are compatible with human body as a result of damage of cartilage tissue due to various health problems. These prostheses consist of polyethylene parts between the Tib...

Strategies That Transform the Retail

The objective of the present investigation is to analyze the strategies that the companies implement and the changes that originate in the retail trade and the retail trade and in the commercial establishments in the dev...

A Comparison of Five Methods for Missing Value Imputation in Data Sets

The missing values in the data sets do not allow for accurate analysis. Therefore, the correct imputation of missing values has become the focus of attention of researchers in recent years. This paper focuses on a compar...

A Reduced Reference Metric for Enhanced 3D Video Perception

Currently, one of the trending research topics among the researchers assisting to the enhancement of the 3D video services relies on the 3 Dimensional (3D) video Quality of Experience (QoE) prediction metric development...

Download PDF file
  • EP ID EP35729
  • DOI -
  • Views 308
  • Downloads 0

How To Cite

Burak Öztürk, Levent Uğur, Fehmi Erzincanlı, Özkan Küçük (2018). Optimization of Polyethylene Inserts Design Geometry of Total Knee Prosthesis. International Scientific and Vocational Studies Journal, 2(2), -. https://europub.co.uk/articles/-A-35729