Optimum Scheme for Insulation System in HV Generator Based on Electromagnetic Analysis
Journal Title: Engineering, Technology & Applied Science Research - Year 2011, Vol 1, Issue 3
Abstract
Electrical insulations are one of the basic parts of electrical machinery in any sizes and characteristics. Focusing on insulating, studies on the operation of industrial-electrical machinery came to the fact that the most important part of a machine is the Stator. This fact reveals the requirement for inspection of the electrical machine insulation along with the electromagnetic tensions. Therefore with respect to insulation system improvement of stator, the HV generator can be optimized. Dielectric parameters such as insulation thickness, spacing, material types, geometry of winding and slot are major design consideration. A very powerful method available to analyze electromagnetic performance is Finite Element Method (FEM) which is used in this paper. The analysis of various stator coil and slot configurations are used to design the better dielectric system to reduce electrical stresses in order to increase the power of generator in the same volume of core. These processes of optimization have been done according the proposed algorithm. In this algorithm the technical constraints have been considered. This paper describes the process used to perform classical design and improvement analysis of stator slot’s insulation with respect to objective function and constraints.
Authors and Affiliations
D. Azizi, A. Gholami
A Comparison Among Different Parameters for the Design of a Photovoltaic/Thermal System Using Computational Fluid Dynamics
The purpose of this paper is to compare several fins, duct height, and velocity magnitudes to acquire a PhotoVoltaic/Thermal system designed through Computational Fluid Dynamics. Simulation of different fins (rectangular...
Realization of a Single-Phase Multilevel Inverter for Grid-Connected Photovoltaic System
This paper introduces the implementation of a single-phase multilevel inverter for a grid-connected photovoltaic system. The considered topology contains a full bridge converter tied to an auxiliary circuit made of two p...
Application of Hybrid HS and Tabu Search Algorithm for Optimal Location of FACTS Devices to Reduce Power Losses in Power Systems
Power networks continue to grow following the annual growth of energy demand. As constructing new energy generation facilities bears a high cost, minimizing power grid losses becomes essential to permit low cost energy t...
Performance Evaluation of Traveling Wave Fault Locator for a 220kV Hoa Khanh-Thanh My Transmission Line
This paper presents the traveling wave based fault location methods of SEL-400L, and SFL-2000 available on the market for a 66.9km, 220kV Hoa Khanh-Thanh My transmission line in Central Viet Nam, such as single-ended, an...
A Reactive Power Based Reference Model for Adaptive Control Strategy in a SEIG
In this paper, a new control strategy is proposed for a three-phase squirrel-cage self-excited induction generator (SEIG) connected to a variable speed wind turbine in autonomous mode. In order to improve the dynamic per...