Outcome of Semicontinuous, Non Pledgetted Mono Filament Suture Technique for Aortic Valve Replacement

Journal Title: Journal of Cardiovascular Medicine and Surgery - Year 2018, Vol 4, Issue 2

Abstract

Context: The semi continuous monofilament suturing technique has been proposed as a viable alternative to interrupted pledgetted technique for aortic valve replacement. It is a quick, simple technique and may reduce prosthetic material exposure. Aims: To compare outcome of semi continuous versus interrupted pledgetted suturing techniques for aortic valve replacement. Settings and Design: Prospective study to compare suturing techniques for aortic valve replacement in our institution. Methods and Material: 330 patients who underwent isolated aortic valve replacement were included of which 220 patients underwent interrupted (group I) and 110 (group II) semicontinuous technique. Patient characteristics, operative and early post operative data were compared. Statistical analysis used: Baseline characteristics were compared using Z test. Student’s t test was used to compare operative data and complication rates. A p value of <0.005 was considered significant. Results: Analysis showed that the CPB and cross clamp time was significantly shorter and valve size used was atleast one size larger in the semicontinuous group. Valve thrombosis was seen in 3 patients in group I and no patient in group II. They were managed conservatively. Paravalvular leak was seen in 2 patients in group II. Both the patients had native annulus >25mm and regurgitation type with minimal fibrosis of the annulus. Both patients were subsequently reoperated. Conclusions: Semicontinuous suturing technique for aortic valve replacement is viable with lesser CPB and cross clamp time with larger size valve implantation. It is associated with lesser valve thrombosis. Careful selection of patients can avoid complication of paravalvular leaks.

Authors and Affiliations

Satish Govindaiah

Keywords

Related Articles

Outcome of Semicontinuous, Non Pledgetted Mono Filament Suture Technique for Aortic Valve Replacement

Context: The semi continuous monofilament suturing technique has been proposed as a viable alternative to interrupted pledgetted technique for aortic valve replacement. It is a quick, simple technique and may reduce pros...

Early Results of Left Atrial Reduction Plasty in Patients Undergoing Mitral Valve Replacement

Objective: To study the early outcomes of left atrial reduction plasty in patient undergoing mitral valve surgery with giant left atrium. Methods: We surgically excised the redundant left atrial wall in order to reduce t...

Etiology, Management & Outcome of Ventricular Tachycardia in Structural Heart Disease Patients in Indian Context

Introduction: Ventricular tachycardia (VT) encompasses all the tachycardia’s originating in the ventricular myocardium or the specialized conductive tissue distal to the atrioventricular node. Structural heart disease (S...

Retroperitoneal Fibrosis Masquerading as Malignancy: A Clinical Dilemma-Case Report

Retroperitoneal fibrosis is a rare vascular connective tissue disease of unknown aetiology, typically presenting as inflammation within the retroperitoneum with the resultant mass effect of the pathological processes inv...

Cardiopulmonary Exercise Testing in Apparently Healthy Indian Male Population: A Pilot Study

Introduction: CR fitness is important for performing daily activities and mobility. It has been reported that VO2 peak values below 20mL * kg−1* min−1 is associated with limited physical function for instrumental activit...

Download PDF file
  • EP ID EP563686
  • DOI 10.21088/jcms.2454.7123.4218.15
  • Views 101
  • Downloads 0

How To Cite

Satish Govindaiah (2018). Outcome of Semicontinuous, Non Pledgetted Mono Filament Suture Technique for Aortic Valve Replacement. Journal of Cardiovascular Medicine and Surgery, 4(2), 159-164. https://europub.co.uk/articles/-A-563686