Parameter Estimation of Neutral Grounding Reactor for a Single Line to Ground Fault for Transformer
Journal Title: International Journal of Trend in Scientific Research and Development - Year 2019, Vol 3, Issue 3
Abstract
Single line to ground faults are the most prominent faults in the power system. This may damage the generators and transformers in the system ultimately leading to its failure. Introducing a neutral grounding reactor between the neutral and ground in the high voltage system, will reduce the fault current and hence will protect the power system components. . This paper will discuss the advantages, operation, application and selection of the neutral grounding reactor for transformer. by Snehal Pimpalkar | Mr. Mahesh Mankar "Parameter Estimation of Neutral Grounding Reactor for a Single Line to Ground Fault for Transformer" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-3 , April 2019, URL: https://www.ijtsrd.com/papers/ijtsrd23030.pdf Paper URL: https://www.ijtsrd.com/engineering/electrical-engineering/23030/parameter-estimation-of-neutral-grounding-reactor-for-a-single-line-to-ground-fault-for-transformer/snehal-pimpalkar
Calibration of Environmental Sensor Data Using a Linear Regression Technique
The linear regression is a linear approach for modeling the relationship between a scalar dependent variable y and one or more explanatory variables denoted X. A linear regression analysis method is used to improve the p...
Heat Load Calculations and Duct Design for Commercial Building G 2
The modern commercial or office building consists of the HVAC system which is Heating, Ventilation, Air conditioned. In this report, we'll going to identify the purpose and goals of HVAC system, describe HVAC types, desc...
Efficient Design of 2 1 MUX Multiplexer using Nanotechnology Based on QCA
Quantum Dot Cellular Automata is a new technology which overcomes of the of CMOS limitations. It is an novel advanced nano-technology that revolves around the single-electron position control. It is one of the most effic...
Comparative Analysis of G.M Tube Characteristics Using (Ba-133) Gamma Source and (Sr-90) Beta Test Source
The study is a recap of experimental physics which compares the G.M tube characteristics of (Ba-133) and (Sr-90) source respectively. SPECTECH ST360 Counter was used for this experiment. The test sources where placed 2cm...
The Importation of Second Handed Vehicles and their Effects on Cameroon’s Economy and Environment
This paper examines the importation of second handed vehicles and their effects on Cameroon’s economy and environment. Although the legal environment has been unfavorable towards the importation of second handed vehicles...