Abstract

In this study, the energy and exergy analysis of an ideal Rankin cycle with reheat is presented. The primary objectives of this paper are to analyze the system components separately and to identify and quantify the sites having largest energy and exergy losses at cycle. In addition, the effect of varying the condenser pressure on this analysis will also be presented. The performance of the plant was estimated by a component-wise modeling and a detailed break-up of energy and exergy losses for the considered plant has been presented. Energy losses mainly occurred in the condenser where 2126KW is lost to the environment while nothing was lost from the boiler system because it assumed adiabatic. The percentage ratio of the exergy destruction to the total exergy destruction was found to be maximum in the boiler system 86.27% and then condenser and stack gas 13.73%. In addition, the calculated thermal efficiency was 38.39 % while the exergy efficiency of the power cycle was 45.85%. The boiler is the major source of irreversibilities. For improvement the power plant efficiency the effect condenser pressure has been studied.

Authors and Affiliations

J. Soundhar, M. Thambi Durai, R. Vijay, M. Siva

Keywords

Related Articles

Dynamics of Water Weed Eichhornia Crassipes: A Review

Water hyacinth (Eichhornia crassipes) an aquatic weed discovered more than 200 years back from south America with a massive spread throughout the world possessing a great challenge of its management, had shown a ray of...

An Overview of Boost Converter Topologies With Passive Snubber

This paper does the analysis of different passive snubber in soft switched boost converters with the help of SIMULINK. Here comparison of the converters with passive snubber have been done to determine which one is effi...

Vehicle Compartment Heat Control Using Phase Change Materials

The Phase change materials (PCM) are those have the ability to observe a huge amount of heat during its phase change from solid to liquid. The ability of PCMs is utilized in heat storing, heat removal applications. Temp...

Prediction Of Weld Bead Geometry Analysis For Disimilar(Al Lm6 &Allm25) Metal Matrix Composites

Metal matrix composites (MMCs) combine a stiff but brittle phase, typically a ceramic, with a more ductile metal matrix. The correct fractional combination of materials can result in a material with improved stiffness,...

Performing Adaptive Channel Equalization by Hybrid Differential Evolution Particle Swarm Optimization

Inter symbol interference is the main obstacles for reliable communications. To mitigate the effects of ISI and to obtain reliable data transmission, An adaptive equalizer is required at the receiver. Equalizer is used...

Download PDF file
  • EP ID EP21468
  • DOI -
  • Views 241
  • Downloads 3

How To Cite

J. Soundhar, M. Thambi Durai, R. Vijay, M. Siva (2015). Parametric Study and Analysis of Varying the Condenser Pressure in Thermal Power Plant. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 3(12), -. https://europub.co.uk/articles/-A-21468