Pengaruh Luas Permukaan Dializer Terhadap Capaian Adekuasi Dialisis pada Penderita Haemodialisis di Rumah Sakit PKU Muhammadiyah Yogyakarta

Journal Title: IJNP (Indonesian Journal of Nursing Practices) - Year 2014, Vol 1, Issue 1

Abstract

General appearance of weakness, skinny, high blood pressure, anemia, itches, darkness skin color and nausea showing inadequate hemodialysis clinically. Based on literature review there are some factors directly infl uencing on adequate hemodialysis, one of them is dialyzer surface area. The research aimed to study the effect of dialyzer surface area on dialysis adequacy on hemodialysis patient in PKU Muhammadiyah Hospital Yogyakarta from May until June 2013. Cross sectional study was done involving 90 respondents through purposive sampling method. The hemodialysis adequacy counted by Kt/V formula. Data was taken during the second session of hemodialysis. The data were examined with Kruskal Wallis. Mean dialysis adequacy was 1,36±0,377. The statistic test result revealed no signifi cant correlation on dialyzer surface area with dialysis adequacy (p=0.880).

Authors and Affiliations

Nur Chayati, Kusman Ibrahim, Maria Komariah

Keywords

Related Articles

Differences Use of Yoga and Self-Tapping Towards Long Pain of Primary Dysmenorrhea on Adolescent

Background: Dysmenorrhea is a common complaint in young women, characterized by pain. Dysmenorrhea pain has a significant impact on women's lives, such as limitations in daily activities. Primary dysmenorrhea can be trea...

Pengaruh Blog Edukatif Tentang Hipertensi Terhadap Pengetahuan Tentang Hipertensi dan Perilaku Diet Hipertensi pada Pasien Hipertensi di Wilayah Kerja Puskesmas Wirobrajan Yogyakarta

ABSTRACT Background: Hypertension is one of the noncommunicable diseases which is still a major problem around the world because of its prevalence remains high and continues to rise. Increasing prevalence of hypertension...

Penerapan Komunikasi Situation, Background, Assesment, Recomendation (SBAR) Pada Perawat Dalam Melaksanakan Handover

Abstrak Latar Belakang: Rumah sakit yang terakreditasi dalam sistem akreditasi KARS 2012 mengarahkan kegiatan RS agar memberikan pelayanan yang memenuhi standar kualitas jaminan rasa aman. Keamanan pelayanan di RS salah...

Attitude and Behavior Sexual among Adolescents in Yogyakarta

Yogyakarta as a tourism city given more impact on attitude and behavior sexuality among adolescents. Notion and ideas about sexuality much influenced by the Globally issued environment. This study is basically on the att...

Efe ktifi tas Kombinasi Terapi Musik Dan SlowDeep Breathing Terhadap Penurunan Tekanan Darah Pada Pasien Hipertensi

Hypertension is an increasing of blood pressure that does not cause symptoms for many years until there is asigniicant organ damage and the cause of the increasing of morbidity and mortality in Indonesia. The combination...

Download PDF file
  • EP ID EP610018
  • DOI -
  • Views 65
  • Downloads 0

How To Cite

Nur Chayati, Kusman Ibrahim, Maria Komariah (2014). Pengaruh Luas Permukaan Dializer Terhadap Capaian Adekuasi Dialisis pada Penderita Haemodialisis di Rumah Sakit PKU Muhammadiyah Yogyakarta. IJNP (Indonesian Journal of Nursing Practices), 1(1), 66-77. https://europub.co.uk/articles/-A-610018