Peracetic acid. Determination in workplace air

Journal Title: Podstawy i Metody Oceny Środowiska Pracy - Year 2015, Vol 31, Issue 3

Abstract

Peracetic acid (PAA) is a colorless liquid. It occurs in a form of a mixture in which it remains in a state of chemical equilibrium with hydrogen peroxide and acetic acid. PAA is frequently used as a bleach, disinfectant and oxidizing agent.The aim of this study was to develop and validate a sensitive method for determining PAA concentrations in workplace air in the range from 1/10 to 2 MAC values, in accordance with the requirements of standard PN-EN 482.The method is based on passing the air with PAA through impinger filled with water. PAA was determined indirectly by determining the product of its reaction with methyl-p-tolyl sulfide (MTS). Studies were performed using high-performance liquid chromatography (HPLC). An Agilent Technologies (Germany) chromatograph, series 1200, with a diode-array detector (DAD) was used in the experiment. An Ultra C18 column (250 x 4.6 mm, dp = 5 μm) with a precolumn (10 x 4.0 mm; Restek, USA) was applied.PAA could be determined in workplace air at the concentration range from 0.08 to 1.6 mg/m3. The use of ultra C18 column makes it possible to determine PAA.PAA absorbed in water with methyl-p-tolyl sulphide (MTS) and corresponding sulphoxide ensure the stability of a samplee. The method is precise, accurate and it meets the criteria for procedures for measuring chemical agents listed in EN 482:2006. This method can be used for assessing occupational exposure to PAA and associated risk to workers’ health. The developed method of determining PAA has been recorded as an analytical procedure (see Appendix).

Authors and Affiliations

Joanna Kowalska, Agnieszka Woźnica

Keywords

Related Articles

Tellur i jego związki.Metoda oznaczania w powietrzu na stanowiskach pracy

W przemyśle tellur jest stosowany jako dodatek stopowy do: stali, stopów ołowiu, magnezu i miedzi. Stosuje się go także do barwienia szkła i porcelany oraz jako katalizator reakcji chemicznych i dodatek do gumy.Tellur dz...

Hexachlorobenzene – inhalable fraction. Documentation of proposed values of occupational exposure limits (OELs)

Hexachlorobenzene is a solid substance, insoluble in water, highly lipophilic with high melting and boiling point and high vapor density. The compound was used in war, electrotechnical, and chemical industries. Nowadays...

Amended method for determining phosphorus pentoxide in workplace air

The method is used for determination of phosphorus pentoxide in the workplace air. The method is based on the absorption of phosphorus pentoxide in water, hydrolysis to orthophosphoric acid, reaction with ammonium mo...

Nanoparticle aerosols filtration using nonwoven filter media – separation mechanisms and experimental results

This paper presents the mechanisms of nanoparticles retention on nonwoven filter media during depth aerosol filtration and the influence of parameters such as particle size, linear velocity and gas temperature, fibre dia...

N,N-Dimetyloacetamid. Oznaczanie w powietrzu środowiska pracy metodą kapilarnej chromatografii gazowej z detekcją płomieniowo-jonizacyjną

N,N-Dimetyloacetamid (DMAC) jest bezbarwną cieczą o charakterystycznym aminowym zapachu.Substancja ta miesza się z większością polarnych i niepolarnych rozpuszczalników organicznych,jak również z wodą. Jest wykorzystywan...

Download PDF file
  • EP ID EP81603
  • DOI -
  • Views 120
  • Downloads 0

How To Cite

Joanna Kowalska, Agnieszka Woźnica (2015). Peracetic acid. Determination in workplace air. Podstawy i Metody Oceny Środowiska Pracy, 31(3), 125-142. https://europub.co.uk/articles/-A-81603