PERFORMANCE ANALYSIS OF OZONE LAYER FRIEN DLY REFRIGERENT AS A POSSIBLE REPLACEMENT OF R - 22 IN VAPOUR COMPRES SION REFRIGERATION SYSTEM

Abstract

The Montreal protocol set out mandatory time table to phase out R - 22 by 2016. This paper hence discusses the alternative of R - 22 in vapor compression refrigeration system. R - 22 is replaced by a mixture of refrigerant R134a,R32,and R152a in a ratio of 0.4:0 .2:0.4 IN MIXTURE 1 and 0.3:0.4:0.3 in MIXTURE 2 by mass respectively .The performance comparison in R - 22 and the mixture refrigerants are made in terms of C.O.P , Variation of density with temp at constant pressure , Variation of enthalpy with temp at constant pressure , Variation of entropy with temp at constant pressure , Global warming potential , Molecular weight and and Ozone depleting potential.

Authors and Affiliations

Ashish Kumar , Dr. Alka Bani Agrawal

Keywords

Related Articles

 Comparative Analysis of IPV6 Based IS-IS and OSPF-V3 Protocols

 This paper deals with the critical issues of OSPF V3 & IS-IS in IPV6. As IPV6 is becoming popular day by day; due to its wide range of applications; and great hierarchy of IPs. But selecting the best protocol...

An E-Learning System Architecture Based on New Business Paradigm Using Cloud Computing

Cloud computing is becoming an adoptable technology for many of the organizations with its dynamic scalability and usage of virtualized resources as a service through the Internet. Cloud computing and its applications...

 Design and Implementation of Intrusion Detection System (Ids) Sensor Deployment

 Network intrusion detection systems provide proactive defense against security threats by detecting and blocking attack-related traffic. This task can be highly complex, and therefore, software-based network intru...

Comparison of different Combining methods and Relaying Techniques in Cooperative Diversity

An ad-hoc network with a sender, a destination and a third station act-ing as a relay is analyzed. The channels are modeled containing thermal noise, Rayleigh fading and path loss. Different combining methods and diver...

 Series Connection Effect on the Current Shunt Measuring Technique for Large Area Multicrystalline Silicon Solar Cells

 The series connection effect on the electrical performance of a large area multicrystalline Silicon solar cell (21 cm × 21 cm) with back contact technology has been considered in a desert area. Short circuit curre...

Download PDF file
  • EP ID EP105948
  • DOI -
  • Views 63
  • Downloads 0

How To Cite

Ashish Kumar, Dr. Alka Bani Agrawal (30). PERFORMANCE ANALYSIS OF OZONE LAYER FRIEN DLY REFRIGERENT AS A POSSIBLE REPLACEMENT OF R - 22 IN VAPOUR COMPRES SION REFRIGERATION SYSTEM. International Journal of Engineering Sciences & Research Technology, 4(6), 292-301. https://europub.co.uk/articles/-A-105948