Abstract

In this paper, performance analysis of stand-alone photovoltaic (SAPV) system for Primary Health Centre in Orlu, Imo state was conducted. The USAID categorisation of health clinics is used to identify the Primary Health Centre as Category I Health Clinic with corresponding daily and yearly energy demand of approximately 11500 Wh/day and 4197.5 KWh/year respectively. PVsyst software solution was used to model and simulate the entire PV system. 22-year air temperature and monthly and annual averaged insolation incident on a horizontal surface obtained from National Aeronautics and Space Administration (NASA) online meteorological portal was used. The results showed that the SAPV system has yearly energy output of 5269Kwh/year with performance ratio of 58.4%, effective operating or nominal efficiency of 8.83%, loss of load probability of 7.1% and unit cost of energy of 81.5 Naira per KWh. The SAPV is designed to be affordable for the Primary Health Centre in Orlu, Imo State, Nigeria.

Authors and Affiliations

Ezenugu Isaac, Anthony Umoren, Nseobong Okpura

Keywords

Related Articles

Performance Analysis of Stand-Alone Photovoltaic (SAPV) System for Category I Health Clinic in Orlu, Imo State, Nigeria

In this paper, performance analysis of stand-alone photovoltaic (SAPV) system for Primary Health Centre in Orlu, Imo state was conducted. The USAID categorisation of health clinics is used to identify the Primary Health...

Design of Dual Band Microstrip Antenna Using Reactive Loading Technique

The need in most communication devices to have two separate operating frequencies for a variety of applications cannot be over emphasized. Microstrip antennas, as part of its inherent characteristics, have the ability to...

Analysis of Environmental and Economic Prospects of Stand-By Solar Powered Systems in Nigeria

Photovoltaic power systems can be used as electrical power source for home to meet its daily energy requirement through direct conversion of solar irradiance into electricity. This paper presents environmental and econom...

Comparative Analysis of the Impact of Frequency on the Radius of Curvature of Single and Double Rounded Edge Hill Obstruction

In this paper, comparative analysis of the impact of frequency on the radius of curvature of single and double rounded edge hill obstruction is studied, particularly when the International Telecommunication Union (ITU) r...

System for Information Extraction from News Sites

The present paper deals with a system for crawling and content extraction from news sites. The system of web crawlers extracts textual and graphic information and checks for multimedia content availability. A part of the...

Download PDF file
  • EP ID EP237022
  • DOI -
  • Views 159
  • Downloads 0

How To Cite

Ezenugu Isaac, Anthony Umoren, Nseobong Okpura (2016). Performance Analysis of Stand-Alone Photovoltaic (SAPV) System for Category I Health Clinic in Orlu, Imo State, Nigeria. Mathematical and Software Engineering, 2(1), 35-47. https://europub.co.uk/articles/-A-237022