Performance Analysis of The Effect on Insertion Guide Vanes For Rectangular Elbow 900 Cross Section

Journal Title: EMITTER International Journal of Engineering Technology - Year 2016, Vol 4, Issue 2

Abstract

The use of elbow or curved pipe in the installation of piping has a loss of pressure (pressure drop) which could lead the power of pump that drive the fluid and decrease the energy efficiency of the system. The pressure drop is caused by the curved shape of the elbow that cause pressure on the outer wall (outter) larger and blocking off the pace of the fluid, and flow pressure losses caused by friction, flow separation and secondary flow. A method that can be used to reduce flow separation and pressure loss in the elbow is by the insertion guide vane. The test model in the form of rectangular elbow 900 with a radius ratio (rc/Dh) = 1.1249 without using a guide vane and number of guide vane insertion one until three guide vanes. With Reynolds number ReDh ≈ 8.6 × 104. The velocity inlet is uniform, the measured variable is static pressure. Static pressure was measured using an inclined manometer. With variation the number of guide vane gives a more effect on the value of pressure drop, the largest pressure drop until 123.35% compared to that without guide vane. The velocity distribution profile on the outlet side becomes more uniform. The magnitude of this pressure drop occurs as a result of the increased flow friction and its secondary flow become smaller.

Authors and Affiliations

Setyo Nugroho, Achmad Arifudin Hidayatulloh

Keywords

Related Articles

Modified GTS Allocation Scheme for IEEE 802.15.4

IEEE 802.15.4 standard is widely used in wireless personal area networks (WPANs). The devices transmit data during two periods: contention access period (CAP) by accessing the channel using CSMA/CA and contention free pe...

Application of Artificial Neural Networks in Modeling Direction Wheelchairs Using Neurosky Mindset Mobile (EEG) Device

The implementation of Artificial Neural Network in prediction the direction of electric wheelchair from brain signal input for physical mobility impairment.. The control of the wheelchair as an effort in improving disabl...

An Implementation of Error Minimization Position Estimate in Wireless Inertial Measurement Unit using Modification ZUPT

Position estimation using WIMU (Wireless Inertial Measurement Unit) is one of emerging technology in the field of indoor positioning systems. WIMU can detect movement and does not depend on GPS signals. The position is t...

Performance Analysis of DTN Using Level Signal Priority Epidemic Routing Protocol

A DTN architecture consists of several nodes that are connected with high dynamic topology. The routing protocol is an important part which determine the DTN performance system. Although DTN is addressed to be tolerant o...

Development of Healthcare Kiosk for Checking Heart Health

The main problem encountered nowadays in the health field, especially in health care is the growing number of population and the decreasing health facilities. In this regard, healthcare kiosk is used as an alternative to...

Download PDF file
  • EP ID EP269532
  • DOI 10.24003/emitter.v4i2.157
  • Views 78
  • Downloads 0

How To Cite

Setyo Nugroho, Achmad Arifudin Hidayatulloh (2016). Performance Analysis of The Effect on Insertion Guide Vanes For Rectangular Elbow 900 Cross Section. EMITTER International Journal of Engineering Technology, 4(2), 358-370. https://europub.co.uk/articles/-A-269532