Performance Evaluation of Transmission Line Protection Characteristics with DSTATCOM Implementation

Abstract

To meet with the ever-enhancing load demands, new transmission lines should be bolted-on in the existing power system but the economic and environmental concerns are major constraints to this addition. Hence utilities have to rely on the existent power system infrastructure with some modifications. To enhance controllability and boost power transfer potential of the existing power system the use of Flexible Alternating Current Transmission System (FACTS) device is the most viable modification. FACTS devices include Static VAR Compensator (SVC), thyristor controlled series capacitor (TCSC), Thyristor Controlled Reactor (TCR), Thyristor Switched Capacitor (TSC) and Self Commutated VAR compensators i.e. Static Synchronous Compensator (DSTATCOM). Among the FACTS devices, DSTATCOM is the most feasible choice because of its capability to furnish both leading and lagging reactive power, faster response time in comparison with others, smaller harmonic content, inrush current generation is minimum and the dynamic performance with variations of voltage is quite good. DSTATCOM has the ability to have effective control over various issues concerning AC power transmission. However, the Parameters of the protection devices in the present power system are set without taking into account the reaction of these FACTS devices. So in order to ascertain stability and reliability of power system, reaction of FACTS devices with the existent protection schemes must be thoroughly investigated. This paper aims to explore the deviations in the performance characteristics of transmission line protection due to installation of DSTATCOM on a 220KV EHV transmission line using theoretical as well as MATLAB/SIMULINK simulation models. The dynamic performance of a DSTATCOM connected to an existing transmission line system is evaluated when large industrial induction motor is started and voltage sags are introduced.

Authors and Affiliations

Yasar Khan, Khalid Mahmood, Sanaullah Ahmad

Keywords

Related Articles

Image Sharpness Metric Based on Algebraic Multi-grid Method

In order to improve Mean Square Error of its reliance on reference images when evaluating image sharpness, the no-reference metric based on algebraic multi-grid is proposed. The proposed metric first reconstructs the ori...

RFID: The Big Player in the Libraries of the Future

This paper suggest the idea of developing an automatic Radio Frequency Identification (RFID)-based system for library search and to observe the current literature to define whether current technology and developed RFID-b...

Design of an Efficient Steganography Model using Lifting based DWT and Modified-LSB Method on FPGA

The data transmission with information hiding is a challenging task in today world. To protect the secret data or image from attackers, the steganography techniques are essential. The steganography is a process of hiding...

Segmentation of Ultrasound Breast Images using Vector Neighborhood with Vector Sequencing on KMCG and augmented KMCG algorithms

B mode ultrasound (US) imaging is popular and important modality to examine the range of clinical problems and also used as complimentary to the mammogram imaging to detect and diagnose the nature breast tumor. To unders...

New Framework for Improving Big Data Analysis Using Mobile Agent

The rising number of applications serving millions of users and dealing with terabytes of data need to a faster processing paradigms. Recently, there is growing enthusiasm for the notion of big data analysis. Big data an...

Download PDF file
  • EP ID EP260005
  • DOI 10.14569/IJACSA.2017.080812
  • Views 104
  • Downloads 0

How To Cite

Yasar Khan, Khalid Mahmood, Sanaullah Ahmad (2017). Performance Evaluation of Transmission Line Protection Characteristics with DSTATCOM Implementation. International Journal of Advanced Computer Science & Applications, 8(8), 89-99. https://europub.co.uk/articles/-A-260005