Abstract

This paper presents the traveling wave based fault location methods of SEL-400L, and SFL-2000 available on the market for a 66.9km, 220kV Hoa Khanh-Thanh My transmission line in Central Viet Nam, such as single-ended, and double-ended, all of which rely on measurements from inductive CTs and capacitive VTs. Focus was given on the building process of a Matlab Simulink model to evaluate these methods. Current and voltage signals were sent to an analog Chebyshev type II filter which passes higher frequency signals at 3kHz and rejects low frequencies signal at 50Hz. After that, these output signals are used in Clarke's transformation for getting 0 and α components. The detail coefficient of the selected components after DWT using Db4 wavelet at decomposition level 1 can be used to determine the fault types, the direction of fault and propose a crest-wave comparison solution to identify exactly the adjacent bus' reflected wave from the fault point's reflected wave for the fault location. Finally, the accuracy of fault location on the transmission line is reviewed by varying various parameters like fault type, fault location and fault resistance on a given power system model.

Authors and Affiliations

K. H. Le, P. H. Vu

Keywords

Related Articles

Evaluation of Moving Average Window Technique as Low-pass Filter in Microprocessor-Based Protecting Relays

Over the last decades, with the increase in the use of harmonic source devices, the filtering process has received more attention than ever before. Digital relays operate according to accurate thresholds and precise sett...

Automating the Classification of Field Leakage Current Waveforms

Leakage current monitoring is widely employed to investigate the performance of high voltage insulators and the development of surface activity. Field measurements offer an exact view of experienced activity and insulato...

A Novel Efficient Sine Wave Inverter with Custom Programmed PWM and Intelligent Control

This article presents an efficient design of a pure sine wave inverter which results in an electronic design with reduced losses. The proposed design incorporates the generation of custom programmed pulse width modulatio...

Effect of Soorh Metakaolin on Concrete Compressive Strength and Durability

Concrete durability is a key aspect for forecasting the expected life time of concrete structures. In this paper, the effect of compressive strength and durability of concrete containing metakaolin developed from a local...

The Effect of Confluence Angle on the Flow Pattern at a Rectangular Open-Channel

Flow connection in channels is a phenomenon which frequently happens in rivers, water and drainage channels and urban sewage systems. The phenomenon appears to be more complex in rivers than in channels, especially at th...

Download PDF file
  • EP ID EP230320
  • DOI -
  • Views 238
  • Downloads 0

How To Cite

K. H. Le, P. H. Vu (2018). Performance Evaluation of Traveling Wave Fault Locator for a 220kV Hoa Khanh-Thanh My Transmission Line. Engineering, Technology & Applied Science Research, 8(4), -. https://europub.co.uk/articles/-A-230320