Performance of DSTATCOM in Conjunction with DG Operation for Power - Quality Improvement

Abstract

With the increase in the use of renewable sources, application of Distributed Generation in the distribution system has acquired more attention. Distributed Generation has become increasingly more accepted since the demand for reliable and secure power systems with high power quality increases. Distributed generation will continue to be an effective energy solution under certain conditions and for certain types of customers, particularly those with needs for emergency power, uninterruptible power. A Distribution static compensator (DSTATCOM) is a shunt compensation device that is generally used to solve power quality problems in the distribution systems. In all electric power systems, power quality issues arise due to high energy demand loads such as pulse loads. In this paper a new algorithm to generate reference voltage for a distribution static compensator (DSTATCOM) operating in voltage-control mode is preferred. The proposed scheme ensures that unity power factor (UPF) is achieved at the load terminal during nominal operation. In this paper, implementing Power quality circuit with voltage source converter in the BLDC Motor drive using Distributed Generation is developed. Simulation work is performed using MATLAB / SIMULINK environment.

Authors and Affiliations

G. Vamsi Krishna

Keywords

Related Articles

Application of Brucella IgM and IgG on Buffy Coat and Serum from Population at Risk, Khartoum, Sudan

Although brucellosis in human is rarely fatal, it can be severely debilitating and disabling. The infection has a tendency towards chronicity and persistence, becoming a granulomatous disease capable of affecting any org...

Simulation of Vedic Om: Monte Carlo Method in Operations Research

A sound is vibrating in the whole of Creation! It is diverting our mind from study of Matter, its limitations and advantages like pharmaceutical properties, for example , forcing us to believe that only by-products are W...

Design 24x7 Water supply scheme for Tarabai Park E.S.R. Zone

This paper deals with details study of design of 24 x 7 water supply scheme.Water is most vital resource for life and is consider as essence of life, in our plant earth 97% of water lies in oceans, 2% is frozen ice state...

Control of Power Flow in Transmission Line Using UPFC

Electrical power systems is a large interrelated network which requires a careful design to maintain the system with constant power flow operation without any limitations. Flexible to improve the system stability of a po...

Use of GPS with Road Mapping in LBS for Route leveraging APIs

A location based service (LBS) is an application for user’s mobile device that requires necessary information about where the mobile device is located. Location-based services shall be query-based and provide the end use...

Download PDF file
  • EP ID EP244009
  • DOI -
  • Views 108
  • Downloads 0

How To Cite

G. Vamsi Krishna (2016). Performance of DSTATCOM in Conjunction with DG Operation for Power - Quality Improvement. International journal of Emerging Trends in Science and Technology, 3(5), 3933-3938. https://europub.co.uk/articles/-A-244009