Performance of electrical stimulated anaerobic baffled reactor for removal of typical pollutants from low-strength municipal wastewater at low temperatures

Journal Title: UNKNOWN - Year 2019, Vol 6, Issue 2

Abstract

Background: Although anaerobic system has been successfully used for treating the strong industrial wastewater, its efficiency for low-strength wastewater as municipal wastewater is not satisfying. This study aimed to enhance the capability of an anaerobic baffled reactor (ABR) for treating municipal wastewater. Methods: A 7-L ABR with 5 compartments was operated for a 287-day period fed with primary effluent from a wastewater treatment plant at 17 to 19°C. The study was conducted in 2 phases. In the first phase, the performance of ABR and in the second phase, the performance of ESABR (ABR integrated with an electrochemical system) were investigated. Results: The results of ABR operation indicated that at hydraulic retention time (HRT) =24 hours, the average removal efficiency of biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), total Kjeldahl nitrogen (TKN), total phosphorous (TP), and log reduction value (LRV) of coliforms were obtained to be 71%, 75%, 79%, 23%, 30.3%, and 5.8 Log, respectively. In this phase, when the HRT was decreased from 24 to 18 hours and from 18 to 14 hours, the removal efficiency of all parameters by the ABR was decreased. After the shift of ABR operation to ESABR, at HRT=24 hours and current density of 0.78 mA/cm2, the performance of the reactor was enhanced, so that the removal efficiency of BOD, COD, TSS, TKN, TP, and LRV of coliforms were achieved 16.8%, 15%, 4%, 10.7%, 49%, and 1 Log, which was greater than those obtained by ABR. Conclusion: According to the results, this technology (SEABR) is suitable for treating the low-strength municipal wastewater.

Authors and Affiliations

Keywords

Related Articles

Adsorption of copper, lead and cadmium from aqueous solutions by activated carbon prepared from saffron leaves

Background: Industrial development has caused the release of various pollutants including heavy metals into the environment. These toxic compounds are extremely dangerous to living beings and the environment due to their...

Application of Taguchi’s experimental design method for optimization of Acid Red 18 removal by electrochemical oxidation process

Background: Electro-oxidation is developed as an electrochemical method to overcome the problems of the conventional decolorization technologies and is an appropriate alternative for the treatment of colored wastewater...

Significance of physicochemical factors in the transmission of Escherichia coli and chloride

Background: Organic manures are the source of many pathogenic bacteria which could be dangerous for human health. Bacterial transmission and retention in soil is important for processes ranging from contaminant degradati...

Catch per unit efforts and impacts of gears on fish abundance in an oxbow lake ecosystem in Eastern India

Background: Oxbow lakes are abundant in indigenous fishes, but they are subject to unsustainable fishing practices, potential overexploitation, and indiscriminate use of fine-meshed fishing gear. To quantify the catch pe...

Nitrate removal from water using alum and ferric chloride: A comparative study of alum and ferric chloride efficiency

Background: Nitrate is an acute and well-known hazardous contaminant, and its contamination of water sources has been a growing concern worldwide in recent years. This study evaluated the feasibility of nitrate removal f...

Download PDF file
  • EP ID EP606095
  • DOI 10.15171/EHEM.2019.14
  • Views 82
  • Downloads 0

How To Cite

(2019). Performance of electrical stimulated anaerobic baffled reactor for removal of typical pollutants from low-strength municipal wastewater at low temperatures. UNKNOWN, 6(2), 121-128. https://europub.co.uk/articles/-A-606095