Abstract

In order to avoid the rapid on and off, the condition of partial load is maintained by the heat storage device. With Plate heat exchanger in the air to water heat pump, the heat storage device is for heating along with large variation of supply, defrosting time and return water temperature. A Water tank and an inner double pipe heat exchanger were included in the heat storage device. The heat storage device can able to reduce on and off times by utilizing the compressor in energy storage, as it consists of appendages and electric heater. In electric heater and electric storage, there is a shortage of heating during defrosting. Under partial load, it reduces on and off times by utilizing the compressor in heat storage device by four times per hour rather than six times per hour. The reduction in on and off times were exposed by the plate heat exchanger performance test. Also, there is a reduction of defrosting time in heat storage device with electric heater unit by 78s and 84s. While it reduces to 30.73ºC in plate heat exchanger, many steady running parameters either inlet heating water temperature of heat storage device or heat storage device with electric heater is about 33ºC. Thus, the enhancement in the unit performance in designed heat storage device is obtained. With air to water heat pumps, it is suitable for new projects.

Authors and Affiliations

G. Saravanan, K. G. Muthurajan, M. Arun Kumar

Keywords

Related Articles

An EPQ Model with Varying Rate of Deterioration and Mixed Demand Pattern

This paper derives the optimal cycle time and total cost of an EPQ model with a variable rate of deterioration and mixed demand pattern. Demand is inventory dependent during the inventory buildup time and constant demand...

DFM & Simulation for Injection Mould of Knob

This work deals with injection moulding simulation of Knob, in which the gate location, diameter and the possible defects during the filling& packing phase is determined and warpage effects under variable shrinkage with...

Experimental Investigation of Solar Dryer using Phase Change Material

The sun is the most important source of heat and light in the universe and also one of the major renewable sources. In many countries, they are utilizing solar energy in the agricultural area to preserve vegetables, frui...

Productivity Improvement through Quality Circle: A Case Study at Calderys Nagpur

Involvement and participation of the workers in the quality and productivity improvement projects in manufacturing industries through Quality Circles results in great benefits for the organizations. Quality Circles (QCs)...

Dynamic Impact Analysis on ATV Upright

Uprights play a vital role carrying the complete wheel assembly with it and attached to vehicle suspension system. The knuckle has to design in order to sustain all the loads acting on the vehicle during the course of dy...

Download PDF file
  • EP ID EP612006
  • DOI 10.24247/ijmperdjun201911
  • Views 58
  • Downloads 0

How To Cite

G. Saravanan, K. G. Muthurajan, M. Arun Kumar (2019). Performance Studies on the Reversing Valve Incorporated Air-to-Water Heat Pump with Heat Storage Device. International Journal of Mechanical and Production Engineering Research and Development (IJMPERD ), 9(3), 109-118. https://europub.co.uk/articles/-A-612006