Performance verification of domestic nucleic acid testing system in blood stations based on T/CSBT
Journal Title: Chinese Journal of Blood Transfusion - Year 2023, Vol 36, Issue 9
Abstract
Objective To explore the performance verification of the Shengxiang automatic NAT system for HBV DNA, HCV RNA and HIV RNA-1 using PCR-fluorescence in the laboratories of blood stations, in order to meet the requirements of T/CSBT and ensure the quality of nucleic acid detection. Methods Samples used in the external quality assessment (EQA) of National Center for Clinical Laboratories of the year 2022 were taken to verify the concordance. The standard materials of HBV DNA, HCV RNA and HIV RNA-1 were used to verify the analytical sensitivity, endogenous interfering substances, repeatability, anti-cross contamination ability and stability. Results The concordance rate of 20 EQA samples was 100%. The analytical sensitivity of HBV DNA, HCV RNA and HIV RNA-1 were all reactive and met T/CSBT. The yielding of HBV DNA, HCV RNA and HIV RNA-1 was affected little with lipemia at 3g/L and hemolysis at 4g/L. The coefficients of variation(CV) of intra-assay and inter-assay which met T/CSBT were all less than 5%, and the intra-assay variation coefficient was less than the inter-assay variation coefficient. The test results of 40 negative samples tested for cross contamination resistance were 100% negative, and 40 positive samples of HBV with 10 000 IU/mL were 100% positive. The stability verification results showed that the detection rate of weak positive samples was 100%. The coefficient of variation of the test results of the reagent after 1 and 5 freeze-thaw cycles were less than 5%,and the difference between the detection Ct value of reagent underwent once freeze-thaw and five-time freeze-thaw was not statistically significant. Conclusion The analytical sensitivity,endogenous interfering substances, repeatability,anti-cross contamination ability,stability and the compliance rate of domestic Shengxiang Gene automatic NAT system and supporting reagents by PCR-fluorescence method all meet T/CSBT, so it can be used for nucleic acid detection in blood screening in blood station laboratory.
Authors and Affiliations
Chuanbang ZANG, Yan WANG, Li WANG
Construction of a rapid depression screening model for blood donors in Guangzhou based on decision tree
Objective To investigate the prevalence of depression in blood donors and analyze the related factors, so as to develop a rapid depression screening model for blood donors. Methods A total of 13 015 street whole blood do...
Effect of ion-exchange chromatography on removal of fibronectin in von Willebrand factor
Objective To study the removal effect of fibronectin(Fn) from von willebrand factor(vWF) by ion-exchange chromatography through processing human coagulation factor Ⅷ chromatographic washing products, in order to select a...
Correlation between electrochemiluminescence immunoassay and western blot confirmation for human T-lymphotropic virus screening in blood donors
Objective To study the application effect of electrochemiluminescence immunoassay (ECLIA) in the screening of human T-lymphotropic virus (HTLV) in blood donors, explore the correlation between COI and confirmed result by...
Health economics evaluation of the cost and effectiveness of gray zone setting in blood ELISA screening
Objective To analyze the cost-effectiveness of ELISA grey area strategy through establishing the health economics model. Methods The serological grey area strategy evaluation model was composed of screening strategy subd...
A software for blood product information management: development and application
Objective To develop a mobile software application named " Component Assistant" and test for its performance in practical work, so as to address the difficulties and problems encountered during the management process of...