Peripheral Smear Validity Along With Automated Analyzer Regarding Platelet Count

Journal Title: Saudi Journal of Medical and Pharmaceutical Sciences - Year 2018, Vol 4, Issue 10

Abstract

Automated counts are being widely accepted in diagnostic field due to various advantages. Despite the sophistication of present day instruments there is still need to depend on manual techniques for primary calibration especially in case of platelet count. Automated analyzer had pitfalls due to mimickers of platelet like particles which validated the manual count in peripheral smear regarding platelet count by leishman’s stain. A cross sectional study was conducted in a tertiary care hospital for 3 months. It includes 1200 venous samples with EDTA as the anticoagulant in vacutainers. Among the routine 100 to 120 samples/day, with platelets < 1,00,000 lakhs /cumm of 500 samples were subjected for study. Samples were processed by Symex 5000 autoanalyzer and compared with manual platelet count by leishman’s stain. About 500 samples with platelets < 100,000 lakh/cu.mm were taken for study. In 384/500(76.8 %)haematology analyzed correlated with peripheral smear review. About 116(23%) were not correlating with peripheral smear findings because it revealed RBC’s and large platelets in peripheral smear. Our study concludes there was significant correlation between automated and manual counts. But this was not applicable for very high or low platelet counts.As platelet count estimation is very important element of the diagnostic and treatment disorder.Peripheral smear examination along with automated analyzer valid in case of high or low value platelet counts.

Authors and Affiliations

Kanmani Devi M, Arun Kumar T

Keywords

Related Articles

A Review on Analytical Methods for Determination of Guaifenesin Alone and In Combination with Other Drugs in Pharmaceutical Formulations

Abstract: Guaifenesin is an expectorant and it is use to treat cough and congestion caused by the common cold, bronchitis, and breathing illness. The drug is official in Indian Pharmacopoiea, British Pharmacopoeia, and U...

Overweight and Obesity among Mentally Ill Patients

Abstract:Obesity is highly prevalent among patients with schizophrenia, depression and bipolar disorder and is more common in persons with these conditions than in the general population. Excess weight is a major risk fa...

Assess the Attitude and Practice of Surgical Team Members Regarding Time Out Protocols in Operation Theatre at Services Hospital Lahore

Abstract: Time out protocol for surgery is very important for the declination of mortality rate because two hundred and thirty four millions surgeries have been performed every day worldwide in which 7 million had advers...

DentinogenesisImperfectaassociated with Type 1 OsteogenesisImperfecta: A Case Report

Abstract:DentinogenesisImperfecta is an autosomal dominant disorder of dentine affecting primary and permanent dentition. Mutation in dentinsialophospho protein on the long arm of chromosome 4 results in this defective d...

Irreducible Acute PosteriorShoulder Dislocation: About A Case

Abstract:Posterior shoulder dislocations are still a challenge for the treating physician. The mechanisms of trauma are varied, which complicates diagnosis. Missed or delayed diagnosis and treatment can have serious dele...

Download PDF file
  • EP ID EP482518
  • DOI -
  • Views 79
  • Downloads 0

How To Cite

Kanmani Devi M, Arun Kumar T (2018). Peripheral Smear Validity Along With Automated Analyzer Regarding Platelet Count. Saudi Journal of Medical and Pharmaceutical Sciences, 4(10), 1157-1159. https://europub.co.uk/articles/-A-482518