Photon Absorption characteristics of some selected Enzyme Inhibitors used in Cancer Research in the Energy range 1 keV-100 GeV

Journal Title: Journal of Radiology and Oncology - Year 2017, Vol 1, Issue 2

Abstract

The absorption parameters such as total mass attenuation coefficients, molecular, atomic, and electronic cross sections, effective atomic numbers and electron densities were calculated for some selected enzyme inhibitors in the photon energy range from 1 keV up to 100 GeV. The changes in the absorption parameters were interpreted with the photoelectric effect, Compton scattering and pair production processes. It is observed that the 2-Imino-1-imidazolidineacetic acid enzyme inhibitor has more radiation shielding feature when compared to other chosen enzyme inhibitors. The present investigation is anticipated to be useful for researchers studying with radiation in several fields and cancer researchers.

Authors and Affiliations

MR Kaçal, HA Karataş, F Akman

Keywords

Related Articles

Autologous grafts in radiotherapy received breast cancer patients

German surgeon, Vincenz Czerny, transplanted a patient’s own lipoma located in the hip to it’s breast after gland excision due to mastitis in 1895. Dr. Vincenza reported that for at least a year he didnt observe any prob...

Investigation of radiation attenuation parameters of some drugs used in Chemotherapy in Wide Energy Region

Objectives: The aim of this study is to compute the radiation attenuation parameters such as mass attenuation coefficient, linear attenuation coefficient, half value layer, mean free path, and effective atomic number for...

Photon Absorption characteristics of some selected Enzyme Inhibitors used in Cancer Research in the Energy range 1 keV-100 GeV

The absorption parameters such as total mass attenuation coefficients, molecular, atomic, and electronic cross sections, effective atomic numbers and electron densities were calculated for some selected enzyme inhibitors...

Inter-Observer Variability of a Commercial Patient Positioning and Verification System in Proton Therapy

Purpose:Accurate patient positioning is crucial in radiation therapy. To fully benefit from the preciseness of proton therapy, image guided patient positioning and verification system is typically utilized in proton ther...

Radiological evaluation of a Chondromyxoid Fibroma

Chondromyxoid fibroma (CMF) is a very rare benign cartilaginous tumor representing less than 0.5% of all bone tumors while also being the rarest cartilaginous bone tumor. Common locations of occurrence include the metaph...

Download PDF file
  • EP ID EP541146
  • DOI 10.29328/journal.jro.1001009
  • Views 85
  • Downloads 0

How To Cite

MR Kaçal, HA Karataş, F Akman (2017). Photon Absorption characteristics of some selected Enzyme Inhibitors used in Cancer Research in the Energy range 1 keV-100 GeV. Journal of Radiology and Oncology, 1(2), 60-68. https://europub.co.uk/articles/-A-541146